Install and Cable the Cabinets 
Page 1-8
Install the System Cabinets 
1
Wall-Mount the Cabinets 
!
CAUTION:
A fully loaded system weighs 58 lbs (26.3 kg). Use lifting precautions. If the doors, 
power unit, and circuit packs are removed, the unit weighs only 29 lbs (13.1 kg).
Install Plywood Backing onto Wall
The plywood and the hardware to mount the plywood are installer-provided.
Single-Cabinet Installation
1. Install a 3/4-inch (2 cm) thick sheet of 2 x 4-foot (0.6 x 1.2 m) plywood 
horizontally onto the wall. See 
The top of the plywood must be at least 54 inches (137 cm) from the floor. 
2 or 3 Vertically Mounted Cabinets
1. Install a 3/4-inch (2 cm) thick sheet of 4 x 8-foot (1.2 x 2.4 m) plywood 
vertically onto the wall. See 
2 Cabinets Vertically Mounted and 1 Cabinet Horizontally Mounted
1. Install a 3/4-inch (2 cm) thick sheet of 4 x 8-foot (1.2 x 2.4 m) plywood 
vertically onto the wall. See 
2. Install a 3/4-inch (2 cm) thick sheet of 2 x 4-foot (0.6 x 1.2 m) sheet of 
plywood horizontally onto the wall. Position the plywood to the right of the 
first sheet, across from Cabinet A.