Lucent Technologies 555-230-128 User Manual

Page of 144
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets  
555-230-128  
Issue 3
May 1998
Install and Cable the Cabinets 
Page 1-49
Activate and Administer the System 
1
4. If all red LEDs remain on, reseat any 
port
 circuit packs displaying red 
LEDs.
5. If the red LEDs remain on, refer to 
DEFINITY Enterprise Communications 
Server Release 6 Maintenance for Compact Modular Cabinets
.
NOTE:
Ignore the red LED on any TN767 or TN464 DS1 circuit pack until 
after it is administered. Refer to 
Chapter 2, ‘‘Installation Completion 
and Cable Pinouts’’
 to set the switches on these circuit packs. 
NOTE:
Alarms appear in the Alarm Log when power is applied to the 
system before all equipment connecting to port circuit packs is 
installed. Some alarms are logged when power is applied, but 
resolve quickly. If no equipment is connected to the port circuit 
packs, alarms associated with these ports can take up to 4 hours to 
log, but clear automatically after all equipment is installed and 
operating correctly.
Table 1-5.
Country Codes
Country Code
Country
Code
USA
1
France
12
Australia
2
Germany
13
Japan
3
Czechoslovakia
14
Italy
4
Russia
15
The Netherlands
5
Argentina
16
Singapore
6
Greece
17
Mexico
7
China
18
Belgium
8
Hong Kong
19
Saudi Arabia
9
Thailand
20
United Kingdom
10
Macedonia
21
Spain
11