Lucent Technologies 555-230-128 User Manual

Page of 144
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Compact Modular Cabinets  
555-230-128  
Issue 3
May 1998
Install and Cable the Cabinets 
Page 1-65
Install and Wire Telephones and Other Equipment 
1
Local and Phantom Power
An attendant console’s maximum distance from the system is limited. 
See 
Table 1-9
Auxiliary Power
The nonessential functions of an attendant console and its optional 26A1 or 24A1 
selector console derive power from an auxiliary power source. Provide auxiliary 
power for an attendant console through this cable so the console remains fully 
operational during short power outages.
NOTE:
Only 1 console can derive auxiliary power from the system and through the 
auxiliary cable located in the trunk/auxiliary field. 
A console’s maximum distance from its auxiliary power source is:
800 feet (244 m) for a 302A1
350 feet (107 m) for a 301B1 and 302C1
An attendant console can also derive auxiliary power from:
Individual 1151A or 1151A2 power supply
MSP-1 power  supply
258A-type adapters
Bulk power supplies such as the 1145A1
Table 1-9.
Attendant Console Cabling Distances
Enhanced Attendant 
Console (302C1) 
24 AWG Wire (0.26 mm2)
26 AWG Wire (0.14 mm
2
)
Feet Meters
Feet Meters
With Selector Console
Phantom powered
800
244
500
152
Locally powered
5000
1524
3400
1037
Without Selector Console
Phantom powered
1400
427
900
274
Locally powered
5000
1524
3400
1037