Lucent Technologies 555-230-220 User Manual

Page of 522
Event Notification Capabilities
Issue  7 May 1998
6-5
Communications Server CallVisor ASAI Protocol Reference
555-230-221.
Considerations
When monitoring is established for a VDN or ACD domain, ECS generates event 
reports as calls arrive at the domain. ECS does not generate event reports for 
calls that are already present (in progress) at ACD or VDN domains when the 
Request Notification is received. The ECS will generate the Call Offered to 
Domain Event Report only if the call is not already sending event reports over an 
Event Notification association related to the entered domain. (This is true for all 
cases, including the case of a call entering or reentering a VDN as a result of the 
Vector Return Destination feature.) Also refer to user scenario 11 in Appendix A, 
“Call Scenarios and Applications” for more information on VDN.
Starting with R5: if a call is already active at a trunk group when Notification is 
requested on the trunk groups, and the ECS then receives charging information 
for that call, then the ECS will generate a Charging Event Request. The Charging 
Event Report is the 
only
 report provided by an Event Notification trunk group 
association. The event notification for trunk groups with the ##### domain will 
provide a Charging Event Report for all trunk groups. Only one Event Notification 
association per system is allowed for the domain type trunk access code. Due to 
the volatility in traffic volume, it is recommended that customers reserve a 
separate ASAI link for any application that invokes the Advice of Charge (AOC) 
feature.
NOTE:
Event Notification capability has evolved over time. Prior to G3V3, only one 
Event Notification per ACD or VDN domain was allowed at any one time. 
G3V3 increased the number of associations that can be simultaneously 
active, to three per ACD or VDN domain. In R6r, the number of Event 
Notification Associations that can be active at a time, has been increased to 
six per ACD or VDN domain. In R6si, the number of Event Notification 
Associations per ACD or VDN domain, is still three.