Lucent Technologies 555-230-220 User Manual

Page of 522
ASAI-Ethernet
Issue  7 May 1998
13-7
and the set of hosts with which it will communicate be a separate LAN 
segment. Customers who do not follow this recommendation are subject to 
an unscrupulous person gaining access to the DEFINITY LAN Gateway 
application in order to commit toll fraud and/or tamper with the real-time 
aspects of CTI applications. (Toll fraud is the unauthorized use of your 
telecommunications system by an unauthorized third party. Under 
applicable law, the customer is responsible for paying for such unauthorized 
usage.) 
Two of the serial cables attached to the TN801 can be used for local and remote 
administration as well as maintenance support.These are RS232 ports that allow 
connectivity to a dumb terminal or to terminal emulation software on a PC. The 
serial cable (labeled DCIU in Figure 13-4) is not currently used.
The first serial cable attached to the TN801 (labeled Maint/Port A in Figure 13-4) 
should be connected to a 9600 baud (or better) modem that allows remote access 
by Lucent Technologies services. This is a similar arrangement to the INADS port 
provided on DEFINITY ECS. To enhance customer security, the modem should 
be turned off except when access by Lucent Technologies is desired. The second 
serial cable attached to the TN801 (labeled Admin/Port B in Figure 13-4) can be 
used for local administration.
Administrative Console Connectivity for MAPD
The MAPD is provided with two serial ports (labeled Maint/Port A and Admin Port 
B in MAPD Figure 13-4) that provide access to the administrative logins. The first 
port labeled “Maint/Port A” is dedicated for remote access by Lucent Technologies 
Services. The second port labeled “Admin/Port B” may be connected to a 
dedicated terminal, or to a shared terminal through an “A-B” ECS. Additionally, 
once the LAN network administration is completed, the administrative application 
may also be accessed by the use of “telnet” from a remote system.
For customers who do not wish to have an additional, physical, permanent 
console, it is recommended that the MAPD be initially administered using a 
temporary terminal, PC, or laptop. Once the LAN administration is completed, 
telnet may be used from any host attached to the isolated segment (such as the 
MAPD client). This allows further (and ongoing) administrative access without the 
need for a permanent console terminal. The overall connectivity scheme is 
depicted in Figure 13-5.