Lucent Technologies 555-230-220 User Manual

Page of 522
Event Reporting and U-Abort Capabilities
3-28
Issue  7 May 1998 
— The call was redirected using the ASAI Redirect Call capability. 
However, if the Redirect Call request was sent over a domain 
control association, then that domain association receives an ACK, 
but does not receive the Call Redirected Event Report.
When the domain-controlled station is an analog phone and an alerting call 
is now alerting elsewhere (gone to coverage or redirected by ASAI 
Redirect Call), either:
— The pick-up feature is used to answer a call alerting an analog 
principal’s station, or
— An analog phone call is sent to coverage due to “no answer” (the 
analog set’s call is redirected).
This event report 
will not
 be sent if the Domain (Station) Control is never 
alerted or if it retains a simulated bridged appearance until the call is 
dropped/disconnected. Examples of situations when this event is not sent 
are:
Bridging
Call forwarding
Calls to a TEG (multifunction set with TEG button)
Cover-All
Coverage/Busy
Incoming PCOL calls (multifunction sets)
Pick-up for multifunction set principals
This event report never follows a Connected Event Report and is always 
preceded by an Alerting Event Report.
Call Redirected Report Items
The following is a list of the items provided with this report:
call_id
This ECS-assigned call identifier is used to associate event reports to calls and 
identify a call the adjunct wants to control. The call identifier is unique within ECS.