Intel® Server Board SE7501WV2 TPS 
Server Management 
Revision 1.0 
 
 
Intel reference number C25653-001 
61
Pin # 
Pin Name 
Signal 
Type/ 
Config 
Description 
38 
AIN3 
P2V5 
input 
Baseboard P2V5 monitor 
39 AIN2 
P5V_STBY_SCALED 
input 
External attenuator=1k/(1k+1k)=0.5 
40 
AIN1 
P1V8_STBY 
input 
Baseboard P1V8_STBY monitor 
41 AIN0 
P3V3_VAUX 
input 
External attenuator=499k/(499+365~=0.58 
42 THERM*/GPIO16 
TP_HEC5_GPIO16 
gpio 
This pin does not yet have a specified 
connection. 
43 
GPIO15 
BMC_CPU2_THRMTRIP_L  input 
Processor Thermal Trip signal from CPU2  
44 
GPIO14 
BMC_CPU1_THRMTRIP_L  input 
Processor Thermal Trip signal from CPU1  
46 GPIO13 
VID_CPU1<3> 
input 
 
45 GPIO12 
VID_CPU1<4> 
input 
 
47 GPIO11 
VID_CPU1<2> 
input 
 
48 GPIO10 
VID_CPU1<1> 
input 
 
 
5.1.1 
Fault Resilient Booting 
The Sahalee BMC implements Fault Resilient Booting (FRB) levels 1, 2, and 3. If the default 
bootstrap processor (BSP) fails to complete the boot process, FRB attempts to boot using an 
alternate processor. 
• 
FRB level 1 is for recovery from a BIST failure detected during POST.
 
This FRB 
recovery is fully handled by BIOS code.
 
 
• 
FRB level 2 is for recovery from a watchdog timeout during POST. The watchdog timer 
for FRB level 2 detection is implemented in the Sahalee BMC. 
• 
FRB level 3 is for recovery from a watchdog timeout on hard reset or power-up. The 
Sahalee BMC provides hardware functionality for this level of FRB. 
5.1.1.1 FRB-1 
In a multiprocessor system, the BIOS registers the application processors in the MP table and 
the ACPI tables. When started by the BSP, if an AP fails to complete initialization within a 
certain time, it is assumed nonfunctional. If the BIOS detects that an application processor has 
failed BIST or is nonfunctional, it requests the BMC to disable that processor. The BMC then 
generates a system reset while disabling the processor; the BIOS will not see the bad processor 
in the next boot cycle. The failing AP is not listed in the MP table (refer to the Multi-Processor 
Specification, Rev. 1.4
), nor in the ACPI APIC tables, and is invisible to the operating system. If 
the BIOS detects that the BSP has failed BIST, it sends a request to the BMC to disable the 
present processor. If there is no alternate processor available, the BMC beeps the speaker and 
halts the system. If BMC can find another processor, BSP ownership is transferred to that 
processor via a system reset.  
5.1.1.2 FRB-2 
The second watchdog timer (FRB-2) in the BMC is set for approximately 6 minutes by BIOS and 
is designed to guarantee that the system completes BIOS POST. The FRB-2 timer is enabled 
before the FRB-3 timer is disabled to prevent any “unprotected” window of time.