Mustang Survival MA7214 Leaflet

Page of 2
Inflatable PFD Re-Arm Kit  MA7214
WARNING
·  Use only with specified PFD models.
·  This gas cylinder is under pressure, therefore misuse can 
be dangerous.
·  Do not incinerate, expose to sunlight or store above 120˚F 
(50˚C).
·  Do not throw into open fire or dump at sea.
·  Keep away from children.
·  Dispose of gas cylinders only when empty.
·  Discharge and dispose of corroded or rusty cylinders.
IMPORTANT: Please review and follow additional 
maintenance instructions in your manual.
Re-arming instructions
1  Place the Inflatable PFD 
(Personal Flotation Device) 
on a smooth, flat surface 
and wipe off any water. 
If needed, unpack the 
PFD starting at the zipper 
flap. Access the inflator 
by reaching between the 
cover and cell and pull it 
toward you, turning the 
cell and cover inside out to 
fully expose the inflator for 
re-arming. Hold the CO2 
cylinder through the fabric, 
using one hand (Fig. 1).
2  Insert the metal key between the black locking ring and 
labeled yellow cap. Turn the key counter-clockwise (Fig. 2).
3  Turn the black locking ring counter-clockwise and lift off 
the cap (yellow inflator operating head Fig. 3). Dispose of 
the used cap.
4  Squeeze the sealing ring to elongate and remove the 
inflator body through the sealing ring (Fig. 4).
5  Dispose of the used inflator body (Fig. 5).
6  Check that the new inflator body indicator is green. Insert 
the new inflator body with CO2 cylinder pointing upward 
inside the Inflatable PFD. Let the sealing ring rest on the 
adapter around the four lugs (Fig. 6).
7  Now check the new manual/automatic cap as follows (Fig. 7):
1. Is the single point status indicator showing green? 
2. Is the expiry date OK? 
If YES is the answer to both questions, then proceed as 
follows. If the answer is NO to either question, get a new cap.
FIGURE 8
Figure 1
tube and check that it stays inflated at least overnight. 
Empty the Inflatable PFD again by reversing the oral-
inflation tube dust cap and inserting it into the valve. 
Gently squeeze the inflatable PFD until all air or gas has 
been expelled. Let the Inflatable PFD dry before packing. 
IMPORTANT: Ensure all air is removed before repacking.
 13 Refold the Inflatable PFD in accordance with the repacking 
section in the PFD manual.
8  Hold the CO2 cylinder through the fabric of the Inflatable 
PFD (Fig 8a). Position the replacement cap with the water 
inlet valve pointing to the right and press firmly onto the 
inflator body and sealing ring (Fig. 8b).
9  While pressing FIRMLY onto the inflator body, turn the 
BLACK locking ring clockwise into the locked position (Fig. 
9). Pull on the cap to make sure it has locked onto the 
inflator body.
10 Check: To see that the single point status indicator on the 
cap is green; the pull to inflate lanyard is present and that 
the locking ring is locked.
11 Turn cell and cover right-side out, returning to normal 
state. If your PFD has the black molded inflator cap cover 
(see Fig. 10), position the protective inflator cap cover 
over the inflator body so 
that the single point status 
indicator is visible thrrough 
the inflator cap cover 
window.
12 If your Inflatable PFD has 
been used and/or the 
inflator replaced, always 
inflate through the oral 
Figure 2
LOCKING RING KEY
Figure 3
CAP
Figure 4
INFLATOR BODY
SEALING RING
RED  
INDICATOR
Figure 6
GREEN 
INDICATOR
CAUTION: 
DO NOT TURN 
THE CENTER 
SHAFT
Figure 7
SINGLE 
POINT INDICATOR
WATER 
INLET VALVE
Inflator
Cap Cover
Single Point
Status Indicator
Inflator Cap
Cover Window
Figure 9
Figure 10
BLACK 
LOCKING RING
Figure 8b
90º
Figure 8a
Figure 5
RED INDICATOR
TRASH
Re-arm kit for 
Mustang survival Models:
Trousse de réarmement pour les modèles de V.F.I.  
de 
Mustang survival:
MD3183, MD3184, MD3188 
MD3153, MD3154
PA7214_Rearm_12Aug2009.indd   1-5
8/25/2009   4:34:07 PM