20°
11.  Adjust the tension screw until the proper belt tension is 
recorded by the Browning Belt Tension Checker. The 
recommended deflection force is 150 percent of the Edge 
value or the value given for a new belt in form 5453 included 
with the Browning Belt Tension Checker
WARNING! The surface on which the Motor Base is mounted must be flat.  A base that is distorted or warped will not function 
properly.  If the surface is not flat, correct the condition with shims.
Maintenance
Lubrication
The carriage tubes are provided with holes or fitting for lubrication.  Every six months or as dictated by the application, wipe down the 
carriage rails and tension rod with an oily rag and apply a light grade grease.  Be sure to remove all foreign material from the tubes 
and tension rod.
Changing Belts
Turn the tension rod counter clockwise to move the carriage enough to allow the old belt to be removed.
Repeat steps 7 through 11 of the installation instructions to install the new belt.
Adjusting Belts
Periodic adjustment should not be needed.  However, if it is suspected that the belt tension is not correct, then complete steps 10 and 
11 of the installation instructions.
Allowable Mounting Positions
Floor Mounted
Ceiling Mounted
Wall Mounted Driven 
beside Driver
Browning, Emerson and Emerson Industrial Automation are trademarks of Emerson 
Electric Co. or one of its affiliated companies. 
©2014 Emerson Power Transmission Corp., All Rights Reserved.
MCIM14006E  • Form 9884E • Printed in USA
Wall Mounted Driven 
Above Driver
All other mounting positions contact Application Engineering.