GAS HOOK-UP  
Only the pressure regulator and hose assembly 
supplied with the grill should be used. Any 
replacement pressure regulator and hose assembly 
must be specified by the grill manufacturer. 
 
Total gas consumption (per hour) of the 720-0100-
NG grill with all burners set on “HI”: 
 
Main burners 
            48,000 BTU/Hr. 
Rear burners 
            10,000 BTU/Hr. 
Side burner 
            12,000 BTU/Hr. 
Total 
 
            70,000 BTU/Hr.  
 
LEAK TESTING
 
GENERAL 
Although gas connections on the grill are leak 
tested prior to shipment, a complete gas tightness 
check must be performed at the installation site. 
Periodically check the whole system for leaks 
following the procedures listed below.  
 
If the smell of gas is detected at anytime, you 
should immediately check the entire system for 
leaks. 
 
BEFORE TESTING
 
Make sure all packing materials have been 
removed from the grill, including the burner tie-
down straps. 
 
 WARNING 
Check all gas supply fittings for leaks before each 
use
Do not use the grill until all connections have 
been checked and do not leak.  
 
Do not smoke while leak testing. 
 
Never leak test with an open flame.  
 
Make a soap solution of one part liquid detergent 
and one part water. You will need a spray bottle, 
brush, or rag to apply the solution to the fittings. 
 
TO TEST 
1.  Make sure the control valves are in the “OFF” 
position, and turn on the gas supply.  
 
2.  Check all connections from the natural gas 
regulator and supply valve up to and including 
the connection to the manifold pipe assema964TEMC