KitchenAid KBGN292 User Manual

Page of 48
9
Installation
Instructions —
Built-In Outdoor
Grill 
(non-combustible
construction)
2.
Make gas connections.
A combination of pipe fittings must be
used to connect the grill to the existing
gas line.
This installation must conform with local
codes and ordinances**. In the absence of
local codes, installations must conform
with either the National Fuel Gas Code
ANSI Z223.1, or CAN/CGA-B149.1*
Natural Gas and Propane installation code.
Excessive Weight Hazard
Use two or more people to move
and install grill.
Failure to do so can result in back
or other injury.
WARNING
Natural Gas Use
5.
Open the hood.
valve open
IMPORTANT: If grill is to be installed in a
combustible enclosure, return this unit
and replace it with the model which is
manufactured for use in a combustible
enclosure.
rear of
grill
1/2" grill
gas pipe
flexible gas
connector
3.
Open shutoff valve in the gas
supply line. The valve is open when the
handle is parallel to the gas pipe.
4.
Test all connections by brushing
on an approved non-corrosive leak-
detection solution. Bubbles will show a
leak. Correct any leak found.
• If local codes permit, use an outdoor
flexible stainless steel tubing gas
connector, design-certified by AGA or
CSA International, to connect the grill to
the rigid gas supply line. 5/8" diameter
line is recommended. Using a wrench to
tighten, connect the gas supply to the
grill. Use pipe joint compound on all non-
flared male threads. Do not kink or
damage the flexible connector when
moving the grill.
• Pipe-joint compounds suitable for use
with L.P. gas must be used. Do not use
Teflon
®
tape.
valve closed
® Teflon is a registered trademark of E.I. Du Pont
de Nemours and Company.
WARNING
Fire Hazard
Do not use grill near combustible
materials.
Do not store combustible materials
near grill.
Doing so can result in death or fire.
WARNING
Fire Hazard
Do not install this grill on or near
combustible materials.
Doing so can result in death or fire.
Copies of the standards listed may 
be obtained from:
* CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
** for local codes, contact your local
building inspector
WARNING
Explosion Hazard
Securely tighten all gas connections.
If connected to LP, have a qualified
person make sure gas pressure does
not exceed 11” (28 cm) water column.
Examples of a qualified person
include:
licensed heating personnel,
authorized gas company personnel,
and,
authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
1.
Place grill into outdoor enclosure,
but leave enough room in back to connect
to gas supply.
burner
cap
burner
notch
alignment
tab
6.
For models equipped with
rotisserie, remove the rotisserie’s skewer
from the grill.
7.
For models with side burners.
Remove side burner cover from the top of
the carton that is located on the grill
grate. Remove bubble wrap from side
burner cover and set aside.
Open carton located on the grill grate.
Remove side burner grate, unwrap and
set aside.
Remove burners and burner caps from
carton and unwrap. Install each set of
burners and caps inside the side burner
cavity as shown.
Install side 
burner grate 
and cover 
(with extension 
toward grill) 
as shown.
Properly dispose 
of all packing 
material.
cover
extension
burner
grate