Vermont Casting RADVTEB User Manual

Page of 52
20
20
Radiance Direct Vent Gas Heater 
20012697
7.  Install the appropriate roof support and flashing, 
making certain that the upper flange of the flashing 
base is below the shingles. (Fig. 33)
8.  Install appropriate pipe sections until the vent run 
reaches above the flashing. The enlarged ends of 
the vent sections always face downward.
9.  Install the storm collar and seal around the joints. 
(Fig. 33)
10. Add additional vent lengths to achieve the proper 
overall height.
11. Apply cement to the inner and outer termination col-
lars and install the terminal cap.
ST222
vent thru ceiling
12/99
#7DVAIS
Attic Insulation 
Shield
#7DVFS
Firestop in 
Upper Floor
#7DVFS 
Firestop in 
Ceiling
Use Four 
8d Nails
ST222
Fig. 32  Install firestops and attic insulation shield.
ST221
vent thru roof
12/99
Storm Collar
Sealant
Upper 
edge of 
flange goes 
under upper 
shingles
Flashing
#7DVSKV 
(A, B, or 
F) Roof 
Support
Use three #5 
sheet metal 
screws at 
each joint
ST221
Fig. 33  Roof support and flashing.
Selkirk Direct-Temp Metalbestos Direct 
Vent System
Installation Instructions
1.  Determine whether the length of pipe fits the appli-
ance outlet by attempting to engage the parts. If the 
parts engage smoothly, proceed to Step 2. If ob-
structions, interference or loose fit is noted, contact 
the appliance manufacturer or Selkirk Metalbestos 
with the dimensions of the appliance outlet.
2.  Slide the length of pipe over the appliance outlet a 
minimum of 1¹⁄₂” and screw to the appliance outlet 
collar using a minimum of two (2) #8 x 1/4” sheet 
metal screws.
Appliance Adapter (AAV)
The appliance adapter (AAV) adapts DIRECT-TEMP to 
most direct vent appliances incorporating outlet collars 
configured to receive most common 4” (ID) 6⁵⁄₈” (OD) or 
5” (ID) by 8” (OD) “Twist Lock” Style, direct vent sys-
tems.
The adapter incorporates two (2) indentations on the 
outer wall of the inlet end, which are designed to “Twist 
Lock” into place upon attachment to the appliance 
outlet. Align the adapter indentations with the entry 
slots of the appliance outlet and slide together. Turn the 
adapter clockwise approximately one-quarter turn to 
lock in place. The outlet end of the adapter is standard 
DIRECT-TEMP construction.
Framing Dimension Table 1
 
Model DT  Ceiling Support (CS)  Cathedral Ceiling  Wall Thimble 
 Diameter 
Firestop (FS) 
Support CCS) 
(WT)
 
4” 
8¹⁄₄” x 8¹⁄₄” 
10⁵⁄₈” x 10⁵⁄₈” 
8¹⁄₄” x 8¹⁄₄”
 
5”  
10¹⁄₈” x 10¹⁄₈” 
14¹⁄₂” x 14¹⁄₂” 
10¹⁄₈” x 10¹⁄₈”
Use of Sealant
It is not required to apply or use sealant on the inner 
liner of DIRECT-TEMP. For outer wall joint sealing 
considerations, follow appliance manufacturer recom-
mendations.
Joint Connection:
The pipe and elbows are assembled by inserting the 
outlet (male) end of a length of pipe or elbow into the in-
let (female) end of an adjacent length of pipe or elbow. 
Make sure the outlet end is fully seated within the inlet 
end of the adjoining section and the gasket, located on 
the inner liner of the inlet section is fully enclosed by the 
inner liner of the outlet of the adjoining section. Push 
in the Lock Tab such that it becomes seated within the 
inward groove of the adjoining section. This locks the 
joint in place. (Fig. 34)
Supporting DIRECT-TEMP: Vertical Support
Vertical installations can be supported by two methods:
Ceiling Support (CS) (used in flat ceiling installation) 
comes with a support plate and a support collar. Install