4. Tighten the locking screw against the bottom collar of the 
20 lb LP gas fuel tank to secure.
5. Screw the gas pressure regulator/hose assembly to the 20 lb 
LP gas fuel tank as shown. (To disconnect, turn off the gas 
supply to the 20 lb LP gas fuel tank, then unscrew the gas 
pressure regulator/hose assembly from the 20 lb LP gas fuel 
tank as shown.)
6. Turn on the gas supply. Wait a few minutes for gas to move 
through the gas line.
7. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
8. Slide the tank tray back into the cabinet and lock into place.
9. The batteries are not factory installed. The 1.5-volt “D” size 
alkaline batteries are located in the accessory box on the grill 
grate. Install the batteries at this time following the 
instructions in the “Replacing the Batteries” section. 
10. Go to “Plug in Grill” in this section.
Gas Connection to Natural Gas or Local LP Gas
This installation must conform with local codes and ordinances. 
In the absence of local codes, installations must conform with 
either the National Fuel Gas Code ANSI Z223.1, or CAN/CGA-
B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the 
grill to the existing gas line.
If local codes permit, use an outdoor flexible stainless 
steel tubing gas connector, design-certified by CSA 
International, to connect the grill to the rigid gas supply 
line. A 
⁵⁄₈" diameter line is recommended. Using a wrench 
to tighten, connect the gas supply to the grill. Use pipe-
joint compound on all non-flared male threads. Do not 
kink or damage the flexible connector when moving the 
grill.
A. Locking screw
B. Mounting hole
C. Bottom collar
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
A
B
C
A
B
connect
disconnect
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” 
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 11” (28 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.