Hearth & Home Technologies 42 User Manual

Page of 44
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Montana US-CAN • 4039-156 Rev K • 7/11
5
Getting Started 
A. Design and Installation Considerations
Draft  is  the  pressure  difference  needed  to  vent  fireplaces 
successfully. Considerations for successful draft include:
•  Location of fireplace and chimney
Check building codes prior to installation.
•  Installation  MUST  comply  with  local,  regional, 
state and national codes and regulations.
•  Consult insurance carrier, local building inspector, 
fire officials or authorities having jurisdiction about 
restrictions, installation inspection, and permits.
CAUTION
When planning a fireplace installation, it is necessary to de-
termine the following information before installing:
•  Where  the  fireplace  is  to  be  installed.  See  Sections 
3 and 4.
•  The vent system configuration to be used. See Sections 
5 and 6.
•  Framing and finishing details. See Sections 3, 6 and 8.
•  Whether  optional  accessories  are  desired.  See 
Section 12.
Moisture Resistance:
This outdoor fireplace will shed moderate amounts of water, 
but  is  not  waterproof.  Water  and  condensing  water  vapor 
may enter the chase under certain conditions.
The fireplace will not perform as an exterior wall. Moisture 
penetration must be considered for construction that places 
the fireplace in structure walls or on moisture sensitive sur-
faces.
When installed on exterior walls: Hearth & Home Tech-
nologies  recommends  that  the  fireplace  chase  be  con-
structed  outside  the  structure’s  weather  envelope.  Where 
the platform meets the wall, use a flashing detail similar to 
that required for attached decks. Chase platforms, including 
hearths should slope away from the structure at 1/8 in. to 
1/4 in. per foot. The fireplace can be shimmed level.
When installed on surfaces where water may collect or 
cause damage: Hearth & Home Technologies recommends 
that a drainage pan be placed under the unit. This can be 
constructed of metal, adhesive polymer membrane (such as 
ice and water shield) or other suitable materials. A means of 
drainage out of the pan such as tubes or weep holes should 
be  provided. A  slope  of  1/8  in.  to  1/4  in.  per  foot  towards 
the drain port is suggested. The fireplace can be shimmed 
level.
Hearths  should  slope  away  from  the  front  of  the  fireplace 
and chase at 1/8 in. to 1/4 in. per foot. Spark strips must be 
on top of any combustible hearth materials used for moisture 
management.
B. Typical Fireplace System
The Outdoor Lifestyle fireplace system consists of the fol-
lowing:
•  Fireplace/integral grate/dual cooling air system
•  Refractory
•  Chimney termination cap
•  Chimney system (SL1100 series pipe is NOT approved 
for Canada)
•  Hearth extension
Optional components include:
•  Glass doors
•  Weather cover
•  SLA10  11-10  in./279-254  mm Adapter  (required  in 
Canada)
Termination Cap 
Chimney System 
Refractory 
Integral Grate 
Hearth Extension 
SLA10 not shown
Figure 2.1  Typical Fireplace System