Mitsubishi Electronics E68 User Manual

Page of 415
3. PROGRAM 
ERROR 
 
I - 60 
 
3. PROGRAM 
ERROR 
(The bold characters are the message displayed in the screen.) 
These alarms occur during automatic operation‚ and the causes of these alarms are mainly program errors 
which occur‚ for instance‚ when mistakes have been made in the preparation of the machining programs or 
when programs which conform to the specification have not been prepared. 
 
Error No. 
Details 
Remedy 
P 10 
EXCS. AXIS No. 
The number of axis addresses 
commanded in the same block exceeds 
the specifications. 
•  Divide the alarm block command into two.  
•  Check the specifications. 
P 11 
AXIS ADR. ERROR  
The axis address commanded by the 
program and the axis address set by the 
parameter do not match. 
•  Revise the axis names in the program. 
P 20 
DIVISION ERROR  
An axis command which cannot be 
divided by the command unit has been 
issued. 
•  Check the program. 
P 29 
NOT ACCEPT CMND 
The normal line control command 
(G40.1, G41.1, G42.1) has been issued 
during the modal in which the normal line 
control is not acceptable. 
•  Check the program. 
P 30 
PARITY H 
The number of holes per character on the 
paper tape is even for EIA code and odd 
for ISO code. 
•  Check the paper tape.  
•  Check the tape puncher and tape reader. 
P 31 
PARITY V  
The number of characters per block on 
the paper tape is odd. 
•  Make the number of characters per block on 
the paper tape even.  
•  Set the parameter parity V selection OFF. 
P 32 
ADDRESS ERROR  
An address not listed in the specifications 
has been used. 
•  Check and revise the program address.  
•  Check and correct the parameters values. 
•  Check the specifications. 
P 33 
FORMAT ERROR  
The command format in the program is 
not correct. 
•  Check the program. 
P 34 
G-CODE ERROR  
A G code not listed in the specifications 
has been used. 
An illegal G code was commanded 
during the coordinate rotation command 
(G68).  
•  Check and correct the G code address in the 
program.