Programming Manual - Basic & Applied Instruction Edition
4 Devices in Detail
4.8 High-Speed Counter [C] (FX3U/FX3UC PLC)
4.8.2
Input assignment for high-speed counters
Inputs X000 to X007 are assigned as shown in the table below according to each high-speed counter number.
When a high-speed counter is used, the filter constant of a corresponding input number in the main unit automatically
changes (X000 to X005: 5 
µs, X006 and X007: 50 µs). Input terminals not used for high-speed counters, however, can
be used as general inputs.
When FX
3U
-4HSX-ADP unit is connected to an FX
3U
 PLC, input terminals inside bold-line frames in the table below
are assigned to the first FX
3U
-4HSX-ADP unit, and other input terminals are assigned to the second FX
3U
-4HSX-ADP
unit.
→ For the input specifications of the FX
3U
-4HSX-ADP, refer to the FX
3U
 Hardware Edition.
→ For the input specifications of the main unit, refer to the Hardware Edition of the main unit.
H/W: Hardware counter
S/W: Software counter
U: Up-counting input
D: Down-counting input
A: A phase input
B: B phase input
R: External reset input
S: External start input
*1.
Cautions on wiring should be considered for these high-speed counters.
→ For the wiring, refer to the Hardware Edition of the main unit.
*2.
Hardware counters are switched to software counters when a comparison set/reset instruction for high-speed
counter (DHSCS, DHSCR, DHSZ or DHSCT) is used.
The counter C253 is switched to a software counter when the logic of the external reset input signal is
reversed.
→ For the condition under which it is handled as a software counter, refer to Subsection 4.8.9.
*3.
When a special auxiliary relay is driven in a program, the input terminals and their associated functions are
switched.
→ For the method to use a software counter as a hardware counter, refer to Subsection 4.8.7.
*4.
In a 2-phase 2-count input counter, the edge count is usually 1. But the edge count can be set to 4 by
combining a special auxiliary relay.
→ For the method on how to use a 2-phase 2-count input counter with on edge count of 4,
refer to Subsection 4.8.8.
Counter No.
Classifica-
tion
Input terminal assignment
X000
X001
X002
X003
X004
X005
X006
X007
1-phase
1-count 
input
C235
*1
H/W
*2
U/D
C236
*1
H/W
*2
U/D
C237
*1
H/W
*2
U/D
C238
*1
H/W
*2
U/D
C239
*1
H/W
*2
U/D
C240
*1
H/W
*2
U/D
C241
S/W
U/D
R
C242
S/W
U/D
R
C243
S/W
U/D
R
C244
S/W
U/D
R
S
C244(OP)
*3
H/W
*2
U/D
C245
S/W
U/D
R
S
C245(OP)
*3
H/W
*2
U/D
1-phase
2-count 
input
C246
*1
H/W
*2
U
D
C247
S/W
U
D
R
C248
S/W
U
D
R
C248(OP)
*1*3
H/W
*2
U
D
C249
S/W
U
D
R
S
C250
S/W
U
D
R
S
2-phase
2-count 
input*
4
C251
*1
H/W
*2
A
B
C252
S/W
A
B
R
C253
*1
H/W
*2
A
B
R
C253(OP)
*3
S/W
A
B
C254
S/W
A
B
R
S
C255
S/W
A
B
R
S