Mitsubishi Electronics FX3G User Manual

Page of 964
256
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
9 Move and Compare – FNC 10 to FNC 19
9.6 FNC 15 – BMOV / Block Move
9.6
FNC 15 – BMOV / Block Move
Outline
This instruction transfers (copies) a specified number of data all at once.
1. Instruction format
2. Set data
3. Applicable devices
S1: This function is supported only in FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 PLCs.
S2: This function is supported only in FX
3U
/FX
3UC
 PLCs.
Explanation of function and operation
BMOV instruction transfers "n" points of data from 
 to 
 all at once.
• If the device number range is exceeded, data is transferred within the possible range.
Transfer is enabled even if the transfer number range is overlapped.
To prevent overwriting before transfer of source data, data is automatically transferred in the order "[1] 
→ [2] → [3]"
according to the number overlap status.
Operand Type
Description
Data Type
Transfer source data or device number storing data
16-bit binary
Transfer destination device number
16-bit binary
n
Number of transferred points [n 
≤ 512]
16-bit binary
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D .b KnX KnY KnM KnS T C D
R
U \G
V Z Modify K H
E
" "
P
S1
S2
S1
S2
n
P
FNC 15
BMOV

Mnemonic
Operation Condition
16-bit Instruction
7 steps
BMOV
BMOVP
Mnemonic
Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
  S
  D
  S
  D
   
S
   
D
FNC 15
BMOV
n
"n" points
S ‚
D ‚
Command
input
S ‚
D ‚
+1
S ‚
+1
D ‚
+(n-1)
S ‚
+(n-1)
D ‚
D9
D10
D11
D10
D11
D12
D11
D12
D13
D10
D11
D12
X001
FNC 15
BMOV
D10
D9
K3
X002
FNC 15
BMOV
D10
D11
K3
[1]
[2]
[3]
[3]
[2]
[1]