13 High-Speed Processing – FNC 50 to FNC 59
13.6 FNC 55 – HSZ / High-Speed Counter Zone Compare
2. Operation
FNC 12
DMOV
K123
D200
FNC 12
MOV
H10
D202
M8002
FNC 12
MOV
K1
D203
FNC 12
DMOV
K234
D204
FNC 12
MOV
H10
D206
FNC 12
MOV
K0
D207
FNC 12
DMOV
K345
D208
FNC 12
MOV
H11
D210
FNC 12
MOV
K1
D211
FNC 12
DMOV
K456
D212
FNC 12
MOV
H11
D214
FNC 12
MOV
K0
D215
FNC 12
DMOV
K567
D216
FNC 12
MOV
H11
D218
FNC 12
MOV
K1
D219
C251
K2,147,483,647
C251
FNC 55
DHSZ
D200
K5
M8130
RST
C251
RST
Y011
Comparison data
Output (Y) number
Output is set or reset.
K1: Output is set.
Comparison data
Output (Y) number
Output is set or reset.
K0: Output is reset.
Comparison data
Output (Y) number
Output is set or reset.
K1: Output is set.
Comparison data
Output (Y) number
Output is set or reset.
K0: Output is reset.
Comparison data
Output (Y) number
Output is set or reset.
K1: Output is set.
Table high-speed comparison mode
Head
device
Number
of lines
Comparison
source
Command
input
Reset
command
input