20 Positioning Control – FNC150 to FNC159
20.8 FNC159 – DRVA / Drive to Absolute
20.8
FNC159 – DRVA / Drive to Absolute
Outline
This instruction executes one-speed positioning by absolute drive. The movement distance from the zero point can be
specified.
→ For explanation of the instruction, refer to the Positioning Control Edition manual.
→ For cautions on using special high-speed output adapters,
refer to the Positioning Control Edition manual.
1. Instruction format
2. Set data
*1.
Setting range: 
−32768 to +32767 for 16-bit operation
                       
−999,999 to +999,999 for 32-bit operation
*2.
Setting range: 10 to 32767 Hz for 16-bit operation
Following range for 32-bit operation
3. Applicable devices
S1 : Specify Y000, Y001 or Y002
*3
 transistor output from main unit, or specify Y000, Y001, Y002
*5
 or Y003
*5
 from a
high-speed output special adapter
*4
.
*3.
Y002 is not available in FX
3G
 PLC (14-point and 24-point type) and FX
3S
/FX
3GC
 PLC.
*4.
High-speed output special adapters can be connected only to FX
3U
 PLC.
*5.
To use Y002 or Y003 with a high-speed output special adapter, connected a second high-speed output
special adapter.
Points                                                                                       
• When using a relay output type or triac output type FX
3U
 PLC, a special high-speed output adapter is required.
• Outputs of special high-speed output adapters work as differential line drivers.
Operand type
Description
Data type
Number of output pulses (absolute address)
*1
16- or 32-bit binary
Output pulse frequency
*2
Device number (Y) from which pulses are to be output
Bit
Device number to which rotation direction signal is output
Pulse output destination
Setting range
FX
3U
 PLC
Special high-speed output adapter
10 to 200,000 (Hz)
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 PLCs Main unit (transistor output)
10 to 100,000 (Hz)
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D .b KnX KnY KnM KnS T C D
R
U \G
V Z Modify K H
E
" "
P
S4
S5
S4
S5
S
1
S
2
S3
FNC 159
DRVA
D
DRVA
16-bit Instruction
9 steps
Mnemonic
Operation Condition
Continuous
Operation
DDRVA
32-bit Instruction
17 steps
Mnemonic
Operation Condition
Continuous
Operation
  
S
1
  
S
2
  
D
1
  
D
2
  
S
1
  
S
2
  
D
1
  
D
2