24 Others – FNC181 to FNC189
24.5 FNC189 – HCMOV / High-Speed Counter Move
24.5
FNC189 – HCMOV / High-Speed Counter Move
Outline
This instruction updates the current value of a specified high-speed counter or ring counter.
The function of this instruction varies depending on the PLC version.
1. Instruction format
2. Set data
*1.
Ring counters (D8099 and D8398) cannot be specified in FX
3UC
 PLCs before Ver. 2.20.
3. Applicable devices
S: Only high-speed counters (C235 to C255) and ring counters (D8099 and D8398) can be specified.
Explanation of function and operation
1. 32-bit operation (DHCMOV)
• The current value of a high-speed counter or ring counter specified in 
 is transferred to [
+1, 
].
• After transfer, the current value of the high-speed counter or ring counter is processed as shown in the table below 
depending on the set value of "n":
Operand Type
Description
Data Type
Device number of high-speed counter or ring counter*
1
 handled as transfer source
32-bit binary
Device number handled as transfer destination
n
Specification to clear the current value of high-speed counter or ring counter
*1
 (transfer
source) after transfer    [clear (K1), no clear (K0)]
16-bit binary
Oper-
and 
Type
Bit Devices
Word Devices
Others
System User
Digit Specification
System User
Special 
Unit
Index
Con-
stant
Real 
Number
Charac-
ter String
Pointer
X Y M T C S D .b KnX KnY KnM KnS T C D R U \G
V Z Modify K H
E
" "
P
S S
n
Device 
[
+1, 
] after instruction is executed
High-speed counter
C235 to C255
Current value of high-speed counter 
 
→  [
+1, 
]
Ring counter
D8099
D8099 
→ 
"0" is stored in 
+1.
D8398
Current value of [D8399, D8398] 
→  [
+1, 
]
"n" set value
Operation
K0 (H0)
Does not clear the current value (no processing).
K1 (H1)
Clears the current value to "0".
D
FNC 189
HCMOV
Mnemonic
Operation Condition
16-bit Instruction
 13 steps DHCMOV
Mnemonic
Operation Condition
Continuous
Operation
32-bit Instruction

S
D
S
D
FNC189
DHCMOV
n
S
D
Command
input
S
D
D
S
D
D
S
D
D
D
D
D
D