2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
1
Introdu
ction
2
Ov
ervi
ew
3
Instruction 
Li
st
4
D
evices 
in Det
ai
l
5
Specifi
ed the
De
vice
 &
 
C
onst
ant
6
Bef
ore
 
Pr
og
ra
mmi
ng
7
Bas
ic 
Instruction
8
FN
C00-FN
C0
9
Program Fl
ow
9
FNC
10-FN
C19
Mov
e & Com
pare
10
FNC
20-FNC
29
Arith. & Lo
gi
Operati
on
2
Setting memory capacity
Caution
• When the memory capacity of the FX
3S
 is 16,000 steps, the program capacity is fixed to 4,000 steps, and the total 
of the comment capacity and the file register capacity is limited to 12,000 steps (24 blocks).
The comment capacity is automatically set when the file register capacity is set.
• FX
3G
/FX
3GC
 PLCs operate in the extension mode when the program capacity is 16,001 steps or more, and operate 
in the standard mode when the program capacity is 16,000 steps or less. 
The instruction execution time is longer in the extension mode than in the standard mode.
Example:
Time required to execute the basic instruction "LD"
Standard mode: 0.21 
µs
Extension mode: 0.42 
µs
• In  FX
3U
/FX
3UC
 PLCs, when symbolic information is stored, it is deleted if the memory capacity set by parameters is 
changed.
After changing the memory capacity, write the symbolic information again.
Set item
Contents of setting
Setting range
Memory Capacity
Set the program memory capacity.
Refer to 
Subsection 
2.7.2 or Sub-
section 2.7.3
Comments Capacity
Set the capacity of comments to be stored in the PLC.
50 device comments/block (500 steps)
Symbolic Information 
Capacity
The symbolic information capacity when the built-in memory or a memory cassette is used is
displayed here based on the "Memory Capacity" value.
Press the [Check Other Items] button to display the symbolic information capacity when a
memory cassette is used.
File Register Capacity
Set the file register capacity.
500 file registers/block (500 steps)
Program Capacity
The number of steps available for sequence program is displayed here.
Special Function 
Memory Capacity
Set whether "Special Function Block Settings", "Positioning Instruction Settings", "Built-in
CC-Link/LT Settings" should be enabled.
Special Function 
Block Settings
Selects the initial value setting function for special function unit/block.
Positioning 
Instruction Settings
Validates the TBL (FNC152) instruction setting function.
Built-in CC-Link/LT 
Settings
Validates the CC-Link/LT station information setting function.