Programming Manual - Basic & Applied Instruction Edition
27 Data Operation 3 – FNC210 to FNC219
27.3 FNC212 – POP / Shift Last Data Read [FILO Control]
• Subtract “1” from the value of the pointer data 
.
Related device
→ For the zero flag use method, refer to Subsection 6.5.2.
Related instructions
Cautions
• When this instruction is programmed in the continuous operation type, the instruction is executed in every operation 
cycle.  As a result, an expected operation may not be achieved.
Usually, program this instruction in the “pulse operation type”, or let this instruction be executed by a “pulsed 
command contact”.
• When the current value of the pointer 
 is “0”, the zero flag M8020 turns ON and the instruction is not 
executed.
Check in advance using a comparison instruction whether the current value of 
 satisfies “1 
≤ 
 
≤ n-1”, 
and then execute this instruction.
• When the current value of the pointer 
 is “1”, “0” is written to 
 and the zero flag M8020 turns ON.
Error
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is stored in
D8067.
• When 
 is larger than “n-1” (error code: K6706)
• When 
 is smaller than “0” (error code: K6706)
Device
Name
Description
M8020
Zero flag
Turns ON when the instruction is executed while the pointer 
 is “0”.
Instruction
Description
SFWR (FNC 38)
Shift write [for FIFO/FILO control]
SFRD (FNC 39)
Shift read [for FIFO control]
   
S
Data area
Pointer
S  +n-2
S  +n-1
S  +6
S  +5
S  +3
S  +2
S  +1
No data area
Pointer
S  +n-2
S  +n-1
S  +6
S  +5
S  +3
S  +2
S  +1
S  +4
In the case of K4
K4
→K3
S  +4
  S
   
S
   
S
   
S
   
S
   
S
   
S
   
S