Mitsubishi Electronics FX3G User Manual

Page of 964
688
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
30 External Device Communication – FNC270 to FNC276
30.2 FNC271 – IVDR / Inverter Drive
2. Inverter instruction codes
The table below shows inverter instruction codes which can be specified in 
.
For instruction codes, refer to the pages explaining computer link in detail in each inverter manual.
*1.
The instruction code "HFD (inverter reset)" does not request a response from the inverter.
Accordingly, even if inverter reset is executed to a station number at which an inverter is not connected, error
does not occur.
It takes about 2.2 seconds to complete execution of inverter reset.
*2.
When resetting the inverter, please specify H9696 as the operand 
 of the IVDR instruction.
Do not use H9966.
*3.
Please write "0" to instruction code HFF (Link parameter expansion setting) just before the IVDR instruction
when writing frequency.
When "0" is not written, writing of the frequency may not be executed normally.
3. Related devices
→ For the instruction execution complete flag use method, refer to Subsection 6.5.2.
*4.
Cleared when PLC power supply is turned from OFF to ON.
*5.
Cleared when the PLC mode switches from STOP to RUN.
*6.
Initial value: -1
Cautions
→ For other cautions, refer to the Data Communication Edition manual.
• It is not permitted to use an "RS (FNC 80)/RS2 (FNC 87)"/"ADPRW (FNC276)"/"FLCRT (FNC300) to FLSTRD 
(FNC305)" instruction and an "IVCK (FNC270) to IVMC (FNC275)" instruction for the same port.
• Two or more inverter communication instructions (FNC270 to FNC275) can be driven for the same port at the same 
time.
PLC applicable version
The table below shows PLC versions applicable to each inverter.
Inverter Instruction 
code (hexadecimal)
Write contents
Applicable inverter
F700
A700
E700
D700
V500
F500
A500
E500
S500
HFB
Operation mode
HF3
Special monitor selection 
number
HF9
Run command (expansion)
HFA
Run command
HEE
Set frequency (EEPROM)
*3
HED
Set frequency (RAM)
*3
HFD
*1
Inverter reset
*2
HF4
Alarm definition batch clear
HFC
Parameter all clear
HFC
User clear
HFF
Link parameter extended setting
Number
Description
Number
Description
ch1
ch2
ch1
ch2
M8029
Instruction execution complete
D8063
D8438
Error code of serial communication error
*4
M8063
M8438 Serial communication error
*4
D8150
D8155
Response wait time in inverter communication
*4
M8151
M8156 Inverter communicating
D8151
D8156
Step number in inverter communication
*6
M8152
M8157 Inverter communication error
*5
D8152
D8157
Error code of inverter communication error
*5
M8153
M8158 Inverter communication error latch
*5
D8153
D8158
Latch of inverter communication error occurrence
step
*5*6
M8154
M8159 IVBWR instruction error
*5
D8154
D8159
IVBWR instruction error parameter number
*5*6
PLC
FREQROL-V500/F500/A500/E500/S500
FREQROL-F700/A700
FREQROL-E700/D700
FX
3S
Ver. 1.00 or later
FX
3G
Ver. 1.10 or later
FX
3GC
Ver. 1.40 or later
FX
3U
Ver. 2.20 or later
Ver. 2.32 or later
FX
3UC
Ver. 1.00 or later
Ver. 2.20 or later
Ver. 2.32 or later
  
S
2
  
S
2
  
S
3