Mitsubishi Electronics FX3G User Manual

Page of 964
825
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277
-F
NC2
79
Da
ta
 
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed 
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
 
Register C
ontrol
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt 
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
Inform
ati
on
B
Ex
ecuti
on
 T
imes
Clock
[M]8010
Not used
[M]8011
10 ms clock pulse
ON and OFF in 10 ms cycles 
(ON: 5 ms, OFF: 5 ms)
Refer to Subsection 37.2.6.
[M]8012
100 ms clock pulse
ON and OFF in 100 ms cycles 
(ON: 50 ms, OFF: 50 ms)
Refer to Subsection 37.2.6.
[M]8013
1 sec clock pulse
ON and OFF in 1 sec cycles 
(ON: 500 ms, OFF: 500 ms)
Refer to Subsection 37.2.6.
[M]8014
1 min clock pulse
ON and OFF in 1 min cycles 
(ON: 30 sec, OFF: 30 sec)
Refer to Subsection 37.2.6.
 M 8015
Clock stop and preset
For real time clock
Refer to Subsection 37.2.7.
*3
 M 8016
Time read display is stopped
For real time clock
Refer to Subsection 37.2.7.
*3
 M 8017
±30 seconds correction
For real time clock
Refer to Subsection 37.2.7.
*3
[M]8018
Installation detection (Always ON)
For real time clock
Refer to Subsection 37.2.7.
 (Always ON)
*3
 M 8019
Real time clock (RTC) error
For real time clock
Refer to Subsection 37.2.7.
*3
Flag
[M]8020
Zero
ON when the result of addition/subtraction is 0.
Refer to Subsection 6.5.2 for usage.
[M]8021
Borrow
ON when the result of subtraction is less than
the min. negative number.
Refer to Subsection 6.5.2 for usage.
 M 8022
Carry
ON when 'carry' occurs in result of addition or
when an overflow occurs in result of shift
operation.
Refer to Subsection 6.5.2 for usage.
[M]8023
Not used
 M 8024
*1
BMOV direction specification
(FNC 15)
 M 8025
*2
HSC mode
(FNC 53 to 55)
 M 8026
*2
RAMP mode
(FNC 67)
 M 8027
*2
PR mode
(FNC 77)
 M 8028
100 ms/10 ms timer changeover
Interrupt permission during FROM/TO (FNC 78
and 79) instruction execution
[M]8029
Instruction
execution 
complete
ON when operation such as DSW (FNC 72) is
completed.
Refer to Subsection 6.5.2 for usage.
*1.
The operation varies according to PLC:
-
Not cleared in an FX
1N
/FX
1NC
/FX
2N
/FX
2NC
 PLCs.
-
Cleared in an FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 PLCs when PLC switches from RUN to STOP.
*2.
The operation varies according to PLC:
-
Not cleared in an FX
2N
/FX
2NC
 PLCs.
-
Cleared in an FX
3U
/FX
3UC
 PLCs when PLC switches from RUN to STOP.
*3.
The FX
2NC
 PLC requires the optional memory board (with the real time clock).
Number and 
name
Operation and function
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special 
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC