Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
Positioning [FX
3U
] (Refer to Positioning Control Manual for details.)
[M]8370
[Y003] Pulse output monitor 
(ON: BUSY/ OFF: READY)
*2
 M 8371
*1
[Y003] Clear signal output function enable
*2
 M 8372
*1
[Y003] Zero return direction specification
*2
 M 8373
[Y003] Forward limit
*2
 M 8374
[Y003] Reverse limit
*2
 M 8375
*1
[Y003] DOG signal logic reverse
*2
 M 8376
*1
[Y003] Zero point signal logic reverse
*2
 M 8377
*1
[Y003] Interrupt signal logic reverse
*2
[M]8378
[Y003] Positioning instruction activation
*2
 M 8379
*1
[Y003] Pulse output stop command
*2
RS2 (FNC 87) [ch0] [FX
3G
/FX
3GC
] (Refer to Data Communication Edition for details.)
[M]8370
Not used
[M]8371
*1
RS2 (FNC 87) [ch0] instruction: Send wait flag
 M 8372
*1
RS2 (FNC 87) [ch0] instruction: Send request
D8372
 M 8373
*1
RS2 (FNC 87) [ch0] instruction: 
Receive complete flag
D8373
[M]8374 to [M]8378 Not used
 M 8379
RS2 (FNC 87) [ch0] instruction: Time-out check 
flag
*1.
These devices are cleared when the PLC mode switches from RUN to STOP or when the RS2 instruction
[ch0] turns OFF.
*2.
Available only when two FX
3U
-2HSY-ADP units are connected to an FX
3U
 PLC.
High-Speed Counter Function (Refer to Subsection 4.7.5 and 4.8.5 for details.)
[M]8380
*3
Operation status of C235, C241, C244, C246,
C247, C249, C251, C252, and C254
[M]8381
*3
Operation status of C236
[M]8382
*3
Operation status of C237, C242, and C245
[M]8383
*3
Operation status of C238, C248, C248 (OP),
C250, C253, and C255
[M]8384
*3
Operation status of C239 and C243
[M]8385
*3
Operation status of C240
[M]8386
*3
Operation status of C244 (OP)
[M]8387
*3
Operation status of C245 (OP)
[M]8388
Contact for high-speed counter function change
 M 8389
External reset input logic reverse
 M 8390
Function changeover device for C244
 M 8391
Function changeover device for C245
 M 8392
Function changeover device for C248 and
C253
*3.
Cleared when PLC switches from STOP to RUN.
Interrupt Program
[M]8393
Contact for delay time setting
D8393
[M]8394
HCMOV (FNC189): Drive contact for interrupt
program
[M]8395
Function changeover device for C254
[M]8396
Not used
[M]8397
Ring Counter
 M 8398
Ring counter operation 
(in units of 1ms, 32 bits)
*4
D8398,
D8399
[M]8399
Not used
*4.
1ms ring counter (D8399, D8398) will operate after M8398 turns ON.
Number and 
name
Operation and function
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special 
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC