Mitsubishi Electronics FX3G User Manual

Page of 964
845
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277
-F
NC2
79
Da
ta
 
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed 
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
 
Register C
ontrol
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt 
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
Inform
ati
on
B
Ex
ecuti
on
 T
imes
Stepladder and Annunciator
[D]8040
*1
ON state number 1
The smallest number out of active state
ranging from S0 to S899 and S1000 to
S4095
*2
 is stored in D8040 and the second-
smallest state number is stored in D8041.
Active state numbers are then sequentially
stored in registers up to D8047 (Max. 8
points).
M8047
[D]8041
*1
ON state number 2
[D]8042
*1
ON state number 3
[D]8043
*1
ON state number 4
[D]8044
*1
ON state number 5
[D]8045
*1
ON state number 6
[D]8046
*1
ON state number 7
[D]8047
*1
ON state number 8
[D]8048
Not used
[D]8049
*1
On state minimum 
number
When M8049 is ON, the smallest number out
of active annunciator relay ranging from S900
to S999 is stored in D8049.
M8049
[D]8050 to [D]8059 Not used
*1.
Executed at END instruction.
*2.
S1000 to S4095 are available only in FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 PLCs.
Error Detection (Refer to Chapter 38 for details.)
[D]8060
If the unit or block corresponding to a
programmed I/O number is not actually loaded,
M8060 is set to ON and the first device number
of the erroneous block is written to D8060.
M8060
[D]8061
Error code for PLC hardware error
M8061
[D]8062
Error code for PLC/PP communication error
M8062
Error code for serial communication error 0 [ch0]
*4
M8062
[D]8063
*5
Error code for serial communication error 1 [ch1]
M8063
[D]8064
Error code for parameter error
M8064
[D]8065
Error code for syntax error
M8065
[D]8066
Error code for ladder error
M8066
[D]8067
*6
Error code for operation error
M8067
 D 8068
Operation error step number latched
*7
*7
M8068
[D]8069
*6
Error step number of M8065 to M8067
*8
*8
M8065 to 
M8067
*3.
10 to 337 in FX
3U
/FX
3UC
/FX
2N
/FX
2NC
 PLCs, and 10 to 177 in FX
3G
/FX
3GC
 PLCs.
*4.
Cleared when PLC power supply is turned from OFF to ON.
*5.
The operation varies according to PLC:
-
Cleared in an FX
1S
/FX
1N
/FX
1NC
/FX
2N
/FX
2NC
 when PLC switches from STOP to RUN.
-
Cleared in an FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 PLCs when PLC power supply from OFF to ON.
*6.
Cleared when PLC switches from STOP to RUN.
*7.
In case of 32K steps or more, step number is stored in [D8313, D8312].
*8.
In case of 32K steps or more, step number is stored in [D8315, D8314].
Number and 
name
Content of register
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special 
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC
1 0 2 0
1: Input X   0: Output Y
Device number 
ample: If X020 is unconnected.
BCD converted value
*3
1 0 2 0
1: Input X   0: Output Y
Device number 
Example: If X020 is unconnected.
BCD converted value
*3