37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC277
-F
NC2
79
Da
ta
 
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed 
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
 
Register C
ontrol
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt 
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
Inform
ati
on
B
Ex
ecuti
on
 T
imes
Interrupt Program (Refer to Chapter 36 for details.)
 D 8393
Delay time
Refer to Section 36.4.
M8393
[D]8394
Not used
[D]8395
Symbolic
Information,
Block password
status
Symbolic information storage status and
execution program protection status using the
block password.
*2
*2
[D]8396
Built-in CC-Link/LT setup information
*3
[D]8397
Not used
Ring Counter
 D 8398
Lower Up-operation ring counter of 0 to
2,147,483,647 (in 1-ms units, 32-bit)
*4
M8398
 D 8399
Upper
*1.
"**" indicates areas used by the system.
*2.
Available in Ver. 3.00 or later.
*3.
Only the FX
3UC
-32MT-LT-2 is applicable.
*4.
1ms ring counter (D8399, D8398) will operate after M8398 turns ON.
RS2 (FNC 87) [ch1] (Refer to Data Communication Edition for details.)
 D 8400
RS2 (FNC 87) [ch1]   Communication format
setting
[D]8401
Not used
[D]8402
*5
RS2 (FNC 87) [ch1]   Remaining points of
transmit 
data
M8402
[D]8403
*5
RS2 (FNC 87) [ch1]   Monitoring receive data
points
M8403
[D]8404
Not used
[D]8405
Communication parameter display [ch1]
[D]8406 to [D]8408 Not used
 D 8409
RS2 (FNC 87) [ch1]   Time-out time setting
 D 8410
RS2 (FNC 87) [ch1]   Header 1 and 2
                                    <Default: STX>
 D 8411
RS2 (FNC 87) [ch1]   Header 3 and 4
 D 8412
RS2 (FNC 87) [ch1]   Terminator 1 and 2 
                                    <Default: ETX>
 D 8413
RS2 (FNC 87) [ch1]   Terminator 3 and 4
[D]8414
RS2 (FNC 87) [ch1]   Receive sum (received
data)
[D]8415
RS2 (FNC 87) [ch1]   Receive sum 
(calculated result)
[D]8416
RS2 (FNC 87) [ch1]   Send sum
[D]8417 to [D]8418  Not used
[D]8419
Operation mode display [ch1]
*5.
Cleared when the PLC switches from RUN to STOP.
Number and 
name
Content of register
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special 
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC
Present 
value
Symbolic 
information 
storage
Protection of 
execution 
program
H**00
*1
None
None
H**01
*1
None
Provided
H**10
*1
Provided
None
H**11
*1
Provided
Provided