Mitsubishi Electronics FX3G User Manual

Page of 964
879
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.2 Supplement of Special Devices (M8000 - and D8000 -)
31
FNC277
-F
NC2
79
Da
ta
 
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed 
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
 
Register C
ontrol
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt 
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
Inform
ati
on
B
Ex
ecuti
on
 T
imes
• FX
3S
/FX
3G
/FX
3GC
 PLCs
*1.
In the case of FX
3S
/FX
3GC
 PLCs, all versions are applicable.
*2.
Can be connected only to FX
3G
 PLC (40-point and 60-point type) and FX
3GC
 PLC.
Number
Operation and function
FX
3U
-4AD-ADP
FX
3U
-4DA-ADP
FX
3U
-3A-ADP
Applicable 
version
Ver. 1.00 or later
Ver. 1.00 or later
Ver. 1.20 or later
*1
1st analog special adapter
 M 8280
Input mode switching Ch1
Output mode switching Ch1
Input mode switching Ch1
 M 8281
Input mode switching Ch2
Output mode switching Ch2
Input mode switching Ch2
 M 8282
Input mode switching Ch3
Output mode switching Ch3
Output mode switching
 M 8283
Input mode switching Ch4
Output mode switching Ch4
Not used
 M 8284
Not used
Output hold mode cancel Ch1
Not used
 M 8285
Not used
Output hold mode cancel Ch2
Not used
 M 8286
Not used
Output hold mode cancel Ch3
Output hold mode cancel
 M 8287
Not used
Output hold mode cancel Ch4
Sets whether or not input channel 1 is used.
 M 8288
Not used
Not used
Sets whether or not input channel 2 is used.
 M 8289
Not used
Not used
Sets whether or not output channel is used.
2nd analog special adapter
*2
 M 8290
Input mode switching Ch1
Output mode switching Ch1
Input mode switching Ch1
 M 8291
Input mode switching Ch2
Output mode switching Ch2
Input mode switching Ch2
 M 8292
Input mode switching Ch3
Output mode switching Ch3
Output mode switching
 M 8293
Input mode switching Ch4
Output mode switching Ch4
Not used
 M 8294
Not used
Output hold mode cancel Ch1
Not used
 M 8295
Not used
Output hold mode cancel Ch2
Not used
 M 8296
Not used
Output hold mode cancel Ch3
Output hold mode cancel
 M 8297
Not used
Output hold mode cancel Ch4
Sets whether or not input channel 1 is used.
 M 8298
Not used
Not used
Sets whether or not input channel 2 is used.
 M 8299
Not used
Not used
Sets whether or not output channel is used.
Number
Operation and function
FX
3U
-4AD-PT(W)-ADP
FX
3U
-4AD-TC-ADP
FX
3U
-4AD-PNK-ADP
Applicable 
version
Ver. 1.00 or later
Ver. 1.00 or later
Ver. 1.00 or later
1st analog special adapter
 M 8280
Temperature unit selection
Temperature unit selection
Temperature unit selection
 M 8281
Not used
Type-K/-J switching
Input sensor selection
 M 8282
Not used
Not used
Not used
 M 8283
Not used
Not used
Not used
 M 8284
Not used
Not used
Not used
 M 8285
Not used
Not used
Not used
 M 8286
Not used
Not used
Not used
 M 8287
Not used
Not used
Not used
 M 8288
Not used
Not used
Not used
 M 8289
Not used
Not used
Not used
2nd analog special adapter
*2
 M 8290
Temperature unit selection
Temperature unit selection
Temperature unit selection
 M 8291
Not used
Type-K/-J switching
Input sensor selection
 M 8292
Not used
Not used
Not used
 M 8293
Not used
Not used
Not used
 M 8294
Not used
Not used
Not used
 M 8295
Not used
Not used
Not used
 M 8296
Not used
Not used
Not used
 M 8297
Not used
Not used
Not used
 M 8298
Not used
Not used
Not used
 M 8299
Not used
Not used
Not used