Mitsubishi Electronics FX3G User Manual

Page of 964
882
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
 Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.2 Supplement of Special Devices (M8000 - and D8000 -)
• FX
3S
/FX
3G
/FX
3GC
 PLCs
*1.
In the case of FX
3S
/FX
3G
 PLCs, all versions are applicable.
*2.
Can be connected only to FX
3G
 PLC (40-point and 60-point type) and FX
3GC
 PLC.
Number
Operation and function
FX
3U
-4AD-ADP
FX
3U
-4DA-ADP
FX
3U
-3A-ADP
Applicable 
version
Ver. 1.00 or later
Ver. 1.00 or later
Ver. 1.20 or later
*1
1st analog special adapter
 D 8280
Input data Ch1
Output data Ch1
Input data Ch1
 D 8281
Input data Ch2
Output data Ch2
Input data Ch2
 D 8282
Input data Ch3
Output data Ch3
Output data
 D 8283
Input data Ch4
Output data Ch4
Not used
 D 8284
Number of averaging times
for Ch1 (1 to 4095)
Not used
Number of averaging times
for Ch1 (1 to 4095)
 D 8285
Number of averaging times
for Ch2 (1 to 4095)
Not used
Number of averaging times
for Ch2 (1 to 4095)
 D 8286
Number of averaging times
for Ch3 (1 to 4095)
Not used
Not used
 D 8287
Number of averaging times
for Ch4 (1 to 4095)
Not used
Not used
 D 8288
Error status
Error status
Error status
 D 8289
Model code: K1
Model code: K2
Model code: K50
2nd analog special adapter
*2
 D 8290
Input data Ch1
Output data Ch1
Input data Ch1
 D 8291
Input data Ch2
Output data Ch2
Input data Ch2
 D 8292
Input data Ch3
Output data Ch3
Output data
 D 8293
Input data Ch4
Output data Ch4
Not used
 D 8294
Number of averaging times
for Ch1 (1 to 4095)
Not used
Number of averaging times
for Ch1 (1 to 4095)
 D 8295
Number of averaging times
for Ch2 (1 to 4095)
Not used
Number of averaging times
for Ch2 (1 to 4095)
 D 8296
Number of averaging times
for Ch3 (1 to 4095)
Not used
Not used
 D 8297
Number of averaging times
for Ch4 (1 to 4095)
Not used
Not used
 D 8298
Error status
Error status
Error status
 D 8299
Model code: K1
Model code: K2
Model code: K50