Mitsubishi Electronics FX3G User Manual
850
FX
3S
/FX
3G
/FX
3GC
/FX
3U
/FX
3UC
Series
Programming Manual - Basic & Applied Instruction Edition
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
Inverter Communication Function (Refer to Data Communication Edition for details.)
D 8150
*1
Response wait time of inverter communication
[ch1]
[ch1]
*4
–
–
–
–
–
–
[D]8151
Step number of instruction during inverter
communication [ch1]
Default: -1
communication [ch1]
Default: -1
*4
M8151
–
–
–
–
–
[D]8152
*2
Error code for inverter communication [ch1]
*4
M8152
–
–
–
–
–
[D]8153
*2
Inverter communication error step number
latched [ch1]
Default: -1
latched [ch1]
Default: -1
*4
M8153
–
–
–
–
–
[D]8154
*2
Parameter number when error occurs during
IVBWR (FNC274) instruction [ch1]
Default: -1
IVBWR (FNC274) instruction [ch1]
Default: -1
–
–
–
M8154
–
–
–
–
–
Response waiting time of EXTR (FNC180)
instruction
instruction
–
–
–
–
–
–
–
–
–
*3
*3
D 8155
*1
Response wait time of inverter communication
[ch2]
[ch2]
–
*4
–
–
–
–
–
–
[D]8155
Step number during communication of EXTR
(FNC180) instruction
(FNC180) instruction
–
–
–
–
–
M8155
–
–
–
*3
*3
[D]8156
Step number of instruction during inverter
communication [ch2]
Default: -1
communication [ch2]
Default: -1
–
*4
M8156
–
–
–
–
–
Error code for EXTR (FNC180) instruction
–
–
–
–
–
M8156
–
–
–
*3
*3
[D]8157
*2
Error code for inverter communication [ch2]
–
*4
M8157
–
–
–
–
–
[D]8157
Error step (latched) for EXTR (FNC180)
instruction
Default: -1
instruction
Default: -1
–
–
–
–
–
M8157
–
–
–
*3
*3
[D]8158
*2
Inverter communication error step number
latched [ch2]
Default: -1
latched [ch2]
Default: -1
–
*4
M8158
–
–
–
–
–
[D]8159
*2
Parameter number when error occurs during
IVBWR (FNC274) instruction [ch2]
Default: -1
IVBWR (FNC274) instruction [ch2]
Default: -1
–
–
–
M8159
–
–
–
–
–
*1.
Cleared when PLC power supply is turned from OFF to ON.
*2.
Cleared when PLC switches from STOP to RUN.
*3.
Available in Ver. 3.00 or later.
*4.
Available in Ver. 1.10 or later.
Display Module Function [FX
1S
/FX
1N
]
D 8158
FX
1N
-5DM: Control device (D)
Default: -1
–
–
–
–
–
–
–
–
–
D 8159
FX
1N
-5DM: Control device (M)
Default: -1
–
–
–
–
–
–
–
–
–
FX
1N
-BAT [FX
1N
] (Refer to FX
1N
-BAT Manual for details.)
D 8159
Specification of low battery voltage detection
flag for the FX1N-BAT
Default: -1
flag for the FX1N-BAT
Default: -1
–
–
–
–
–
–
–
–
–
–
Number and
name
Content of register
Applicable model
FX
3S
FX
3G
FX
3GC
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
1NC
FX
2N
FX
2NC