11   MANUAL CONTROL 
 
11.1 Outline of manual control  
11.1.1 Two manual control methods 
"Manual control" refers to control in which positioning data is not used, and a 
positioning operation is carried out in response to signal input from an external source.  
The two types of this "manual control" are explained below.  
 
(1)   JOG operation 
"JOG operation" is a control method in which the machine is moved by only a 
movement amount (pulses are continuously transmitted while the JOG START 
signal is ON). This operation is used to move the workpiece in the direction in 
which the limit signal is ON, when the operation is stopped by turning the limit 
signal OFF to confirm the positioning system connection and obtain the 
positioning data address (refer to section "12.7.4 Teaching function"). 
 
M
Movement continues while 
the JOG START signal is ON.
JOG START signal 
ON
OFF
 
Fig. 11.1 JOG operation 
 
(2)   Manual pulse generator operation 
"Manual pulse generator operation" is a control method in which positioning is 
carried out in response to the No. of pulses input from a manual pulse generator 
(the No. of input pulses is output).  This operation is used for manual fine 
adjustment, etc., when carrying out accurate positioning to obtain the positioning 
address.  
 
M
Movement in response 
to the command pulses
D75P2
Output pulses
Manual pulse generator 
Pulse input
 
Fig. 11.2 Manual pulse generator control