Mitsubishi Electronics AJ65BT-D75P2-S3 User Manual

Page of 666
 
 
 
Appendix - 48 
MELSEC-A
APPENDICES 
 
ZERO POINT RETURN METHOD 
The zero point return methods are shown 
below. The method used depends on the 
machine structure, stopping accuracy, etc. 
Machine zero point returns can be carried out 
when the zero point return parameters are 
written.  
1) Near-point dog method. 
2)  Stopper stop method.   
3) Count method.  
 
 
ZERO POINT RETURN PARAMETER 
This parameter is required when returning to 
the zero point. It is determined by the machine 
side design, so subsequent changes of this 
parameter must be accompanied by changes 
in the machine design.   
The zero point is the reference for positioning 
operations, so if the zero point is lost due to a 
power failure during positioning, or because 
the power is turned OFF and the machine is 
moved manually, etc., it can be restored by 
carrying out a machine zero point return. 
When a machine zero point return command is 
issued, the machine will move in search of the 
near-point dog regardless of the current value, 
and will stop at the zero point. At this time, the 
current value will be rewritten to the zero point 
address. Data cannot be written during 
positioning. With the D75P2, data is always 
written for all axes (from 1, 2 axis). 
Refer to the term "NEAR-POINT DOG". 
 
 
ZERO POINT RETURN REQUEST 
This signal turns ON when there is an error 
with the D75P2. It will turn ON in the following 
situations.  
1)  When the remote station READY signal 
turns from OFF to ON. 
2)  When the machine zero point return starts.   
3)  When the drive unit READY signal turns 
from ON to OFF. 
The user judges whether to carry out a 
machine zero point return in the above 
situations.  
 
 
ZERO POINT SHIFT FUNCTION 
The zero point position can be shifted to the 
plus or minus direction by executing a machine 
zero point return and determining a shift 
amount for the position at the completion of 
the machine zero point return. 
A zero point can be set at a position besides 
the zero point position, or outside the dog 
switch.  
 
 
ZERO POINT SIGNAL 
Indicates PG0 (detected once per rotation) of 
the pulse generator (encoder). Also called a Z 
phase. 
Refer to "PULSE GENERATOR". 
 
PG0
Feedback
pulses
1 axis rotation