iSi North America AMV8 User Manual

Page of 36
35
Wiring Diagram - ADV8
AUTO  RESET
FUSE  3  A
YL
24  VAC
PU
DRAFT
PRESSURE  SWI TCH
9
3.   I F  ANY  OF  THE  ORI GI NAL  WI RE  AS  SUPPLI ED  WI TH  THE  FURNACE  MUST  BE
4.   UNI T  MUST  BE  PERMANENTLY  GROUNDED  AND  CONFORM  TO  N. E. C.   AND  LOCAL  CODES.
2.   MANUFACTURER' S  SPECI FI ED  REPLACEMENT  PARTS  MUST  BE  USED  WHEN  SERVI CI NG.
      REPLACED,   I T  MUST  BE  REPLACED  WI TH  WI RI NG  MATERI AL  HAVI NG  A  TEMPERATURE
1.   SET  HEAT  ANTI CI PATOR  ON  ROOM  THERMOSTAT  AT  0. 7  AMPS.
      RATI NG  OF  AT  LEAST  105
0140F00081P  REV. 0
COLOR  CODES:
YL  YELLOW
GR  GREEN
BK  BLACK
OR  ORANGE
PU  PURPLE
C
RD  RED
BR  BROWN
WH  WHI TE
GY  GRAY
BL  BLUE
PK  PI NK
NOTES:
  OVERCURRENT
PROT.   DEVI CE
° C.   USE  COPPER  CONDUCTORS  ONLY.
ROLL  OUT  LI MI TS  CONTROL
SYSTEM  LOCKOUT  ( RETRI ES/ RECYCLES  EXCEEDED)
4
6
8
7
1
2
3
0
I GNI TOR
SURFACE
FLAME
HOT
SENSOR
W
H
BK
2  STAGE
GAS  VALVE
BR
BL
OR
YL
RD
BLOWER
2
4
V H
U
M
I
D
I
F
I
ER
HI GH FI RE
PRESSURE SWI TCH
SWI TCH  ( PRESS. )
SWI TCH  ( TEMP. )
LI NE  VOLTAGE
FI ELD  WI RI NG
HI GH  VOLTAGE
LOW  VOLTAGE
FACTORY  WI RI NG
I NTEGRATED  CONTROL  MODULE
TR ( 9)
MVC ( 8)
GND ( 4)
I GNI TER
VALVE
GAS
C
MANUAL RESET ROLLOUT
LI MIT  CONTROL
24V HUM.
MI CRO
Y
2
4
V T
H
ER
M
O
S
T
AT
 
C
O
N
N
EC
T
I
O
N
S
C
PU
G
MVL( 7)
PS2 ( 2)
MVH ( 1)
C
PS1 ( 12)
AUXI LI ARY LI MIT
CONTROL
YLO
W2
W1
LI MI T CONTROL
PRI MARY
BR
HL1 ( 6)
TO
HLO ( 11)
NO
PM
HI
PRESSURE
SWI TCH
LOW FI RE
C
NO
PRI MARY LI MIT
CONTROL
WI RI NG  TO  UNI T
MUST  BE  PROPERLY
ON SOME MODELS
I NDUCTOR  COI L
PRESSURE SWI TCH
LOW FI RE
YL
RD
BK
WH
I NDUCED
BR
W
H
W
H
BK
BR
RD
GR
BL
BR
WH
AUXI LI ARY
RD
BL
VAC
115
VAC
24
BK
RD
OR
YL
YL
EAC- N
EAC- H
ELECTRONI C
I
N
T
E
G
R
A
T
E
D
 CO
N
T
RO
L
 
M
O
DU
L
E
I
N
T
E
G
R
A
T
E
D
 CO
N
T
RO
L
 M
O
DUL
E
AI R  CLEANER
HUMI DI FI ER
HOT SURFACE
115 VAC
R
24
HUM.
VAC.
TH ( 5)
XFMR- H
FP ( 3)
I GNI TER
FLAME SENSOR
HI  FI RE
BLOWER  COMPARTMENT
BURNER  COMPARTMENT
BLWR
I ND  LO
HUM- H
I GN- H
I ND HI
I D
XFMR- N
TRANSFORMER
40 VA
HUM- N
I GN- N
I ND- N
CI RCULATOR
J UNCTI ON BOX
I NDUCTOR  COI L
BLWR
LI NE- H
90kBTU,  115 KBTU
MODELS ONLY
I NDOOR
AI R
POLARI ZED  AND
GROUNDED.
BLOWER
CI RCULATOR
DOOR
SWI TCH
LI NE- N
DI SCONNECT
3
1
2
BL
1 0
1 2
1 1
6
4
5
9
7
8
BK    16  WI RE HARNESS
24 VAC.  HUM.
OVERCURRENT  PROTECTI ON  DEVI CE
Ø  / 60  HZ  POWER  SUPPLY  WI TH
DI SCONNECT  POWER
BEFORE  SERVI CI NG.
TO  115VAC/   1
BK
WARNI NG:
L
GND
LI NE- N
LI NE  H
GND
JUNCTI ON BOX
N
DOOR SWI TCH
LI MI T CONTROL
8
7
9
5
4
6
1 1
1 2
1 0
2
1
3
1 4
1 3
1 5
1 2
1 0
1 1
1 5
1 4
1 3
3
6
9
4
5
7
8
1
2
BK
W
H
WH
BR
RD
PU
BK
BK
BK
W
H
BK
BK
BR
BR
5.   USE  COPPER  CONDUCTORS  ONLY
SEE
NOTE 5
PANEL
CONTROL
++ -  USE NEC CLASS 2 WI RE
SEE 
NOTE 5
LOW  VOLTAGE
DEVI CE
OVERCURRENT PROTECTI ON
POWER SUPPLY WI TH
TO 115 VAC/  1/ 60HZ
      9  FLASHES  =  HI GH  FI RE  PRESSURE  SWI TCH  STUCK  OPEN
      CONTI NUOUS  FLASHES  =  115  VOLT  AC  POWER  REVERSED
      8  FLASHES  =  CHECK  I GNI TER  OR  I MPROPER  GROUNDI NG
      5  FLASHES  =  FLAME  SENSED  WI TH  GAS  VALVE  DE- ENERGI ZED
      3  FLASHES  =  LOW  FI RE  PRESSURE  SWI TCH  STUCK  OPEN
      2  FLASHES  =  LOW  FI RE  PRESSURE  SWI TCH  STUCK  CLOSED
      STEADY  ON  =  NORMAL  OPERATI ON
      4  FLASHES  =  THERMAL  PROTECTI VE  DEVI CE  OPEN
      7  FLASHES  =  LOW  FLAME  SENSE  SI GNAL
      1  FLASH      =
TO AVOI
P
O
SSI
B
L
E ELECTRI
CAL SHOCK,
 PERSO
NAL I
N
JURY,
OR DEATH,
 DI
SCO
N
NECT THE POW
E
B
E
FORE SE
RVI
C
IN
G.
WAR
N
IN
G
!