Customer Bulletin 
Commercial Products
 
Rotaries #16-07 
Delayed Deck Engagement 
 
Product:  Groundsmaster 4500 & 4700-D
 
May 7, 2008
 
Affected Units: 
 
Models: 
30856  
30868 
Serial Numbers: 
230000101 – 260000526 
230000101 – 260000279 
Situation:   
Equipment operators may report an abnormally long delay in the engagement of the cutting 
decks on 2003 and newer GM 4500 and 4700-D units.  This delay can extend engagement of 
the decks for 30 seconds or more, and may be intermittent.  Normal deck engagement time is 
approximately 1.5 to 3 seconds. 
The cause for the delay may be an internal malfunction inside the Standard Control Module 
(SCM).  If the SCM is identified to be the source of the problem, a replacement SCM along with 
a PTO Converter Harness will be required to correct the issue.  
Diagnostic Information: 
Remove the Operator’s Console Cover on the right side of the machine.  While sitting in the 
seat, turn the key to the On position, but do not start engine.  Turn on the PTO Switch and 
observe the LED Lights on the Standard Control Module (SCM). The PTO Input light will 
illuminate (on the SCM) but the PTO Output light does not light (or the Ramp-Up Module) for up 
to 30 seconds or more.   Review the machine Operators Manual and the picture below for 
additional details. 
Repair Instructions: 
A replacement SCM (106-9277) and a PTO Converter Harness (110-8839) are required.  The 
SCM is faulty and the Converter Harness will help keep the problem from reoccurring.   
Special Note: 
A PTO Converter Harness can be installed on a properly operating unit.  Installation of this 
harness will ensure the delayed engagement issue does not occur.  For additional information 
regarding this bulletin, contact your local authorized Toro Commercial Products Distributor.