PROBLEMS WITH YOUR FREEZER 
 
You can solve many common freezer problems easily, saving you the cost of a possible service call. Try 
the suggestions below to see if you can solve the problem before calling the servicer. 
 
 
PROBLEM 
POSSIBLE CAUSE 
Freezer does not operate. 
Not plugged in. 
The circuit breaker tripped or a blown fuse. 
The freezer temperature control is set at "0/OFF". 
Compressor  turns on and off frequently. 
The room temperature is hotter than normal. 
A large amount of food has been added to the 
freezer. 
The door is open too often. 
The door is not closed completely. 
The temperature control is not set correctly. 
The door gasket does not seal properly. 
The freezer does not have the correct clearances. 
The freezer has recently been disconnected for a 
period of time.  Four hours are required for the 
freezer to cool down completely. 
Temperature inside the freezer is too warm. 
Temperature control is set too warm.  Turn the 
control to a cooler setting and allow several hours 
for the temperature to stabilize. 
Door is kept open too long or is opened too 
frequently.  Warm air enters the freezer every time 
the door is opened.  Open the door less often. 
The door is not closed completely. 
The door gasket does not seal properly. 
A large amount of warm or hot food might have 
been stored  recently.  Wait until the freezer has 
had a chance to reach its selected temperature.  
The freezer has recently been disconnected for a 
period of time.  Four hours are required for the 
freezer to cool down completely. 
Temperature inside the freezer is too cold. 
Temperature control is set too cold.  Turn the 
control to a warmer setting and allow several 
hours for the temperature to stabilize. 
Fast Freeze switch is turned on.  This causes 
continuous running of the compressor and 
bypasses the temperature control. 
Temperature of external freezer surface is warm. 
The exterior freezer walls can be as much as 30
ο
warmer than room temperature.  This is normal 
while the compressor works to transfer heat from 
inside the freezer cabinet. 
Popping or cracking sound when compressor 
comes on. 
Metal parts undergo expansion and contraction, 
as in hot water pipes.  This is normal.  Sound will 
level off or disappear as freezer continues to run. 
Bubbling or gurgling sound, like water boiling. 
Refrigerant (used to cool freezer) is circulating 
throughout the system.  This is normal. 
Vibrations. 
Check to assure that the freezer is on a level 
surface.   
Floor is uneven or weak.  Freezer rocks on the 
floor when it is moved slightly.  Be sure floor can 
adequately support freezer.  Level the freezer by 
putting wood or metal shims under part of the 
freezer. 
The freezer is touching the wall.  Re-level the 
TROUBLESHOOTING GUIDE