Instructions for the Installer
8
US INSTALLATION ONLY – 3 WIRE BRANCH CIRCUIT
Refer to 
figure 1, where local codes allow the
connection of the ground wire from the applliance
to the branch circuit neutral wire (white wire):
-  The ground wire must be connected first;
-  If local codes permit, connect the green or
yellow-green ground wire from the appliance
and the white wire from the appliance to the
branch circuit neutral wire (white wire).
-  Connect the red and black leads from the oven
to the corresponding leads in the junction box. 
 fig.1)
US INSTALLATION AND CANADIAN INSTALLATION – 4 WIRE BRANCH CIRCUIT
Refer to 
figure 2
-  Disconnect the green or yellow-green from the
white lead.
-  The ground wire must be connected first;
-  Connect the green or yellow-green ground wire
from the appliance to the ground in the junction
box (green colored wire). Do not connect the
grounding wire to the neutral wire in the
junction box.
-  Connect the red and black leads from the
appliance to the corresponding leads in the
junction box.
-  Connect the white wire from the appliance to the
neutral (white) wire in the junction box. 
 fig.2)
Connect to a 20A fuse or circuit breaker. Connect to copper wire only, or, if connecting to
aluminum house wire, use UL-listed or CSA-approved connectors, which are suitable for joining
aluminum with copper wires.