US INSTALLATION ONLY – 3 WIRE BRANCH CIRCUIT
Refer to
figure 1, where local codes allow the
connection of the ground wire from the applliance
to the branch circuit neutral wire (white wire):
to the branch circuit neutral wire (white wire):
- The ground wire must be connected first;
- If local codes permit, connect the green or
yellow-green ground wire from the appliance
and the white wire from the appliance to the
branch circuit neutral wire (white wire).
and the white wire from the appliance to the
branch circuit neutral wire (white wire).
- Connect the red and black leads from the oven
to the corresponding leads in the junction box.
fig.1)
US INSTALLATION AND CANADIAN INSTALLATION – 4 WIRE BRANCH CIRCUIT
Refer to
figure 2,
- Disconnect the green or yellow-green from the
white lead.
- The ground wire must be connected first;
- Connect the green or yellow-green ground wire
from the appliance to the ground in the junction
box (green colored wire). Do not connect the
grounding wire to the neutral wire in the
junction box.
box (green colored wire). Do not connect the
grounding wire to the neutral wire in the
junction box.
- Connect the red and black leads from the
appliance to the corresponding leads in the
junction box.
junction box.
- Connect the white wire from the appliance to the
neutral (white) wire in the junction box.
fig.2)
Connect to a 20A fuse or circuit breaker. Connect to copper wire only, or, if connecting to
aluminum house wire, use UL-listed or CSA-approved connectors, which are suitable for joining
aluminum with copper wires.
aluminum house wire, use UL-listed or CSA-approved connectors, which are suitable for joining
aluminum with copper wires.