Mitsumi electronic MSY-GENA User Manual

Page of 40
22
3. Power factor improvement
Booster coil reactor and POWER FACTOR CORRECTION MODULE rectify AC to DC and control its voltage.
In the motor drive system of sine wave control, power factor can be improved by reducing harmonics. POWER FACTOR 
CORRECTION MODULE and reactor stabilize the voltage of DC supplied to inverter circuit and make its waveform smooth.
4. Intelligent power module
INTELLIGENT POWER MODULE consists of the following components.
· IGBT (x6): Converts DC waveform to 3-phase AC waveform and outputs it.
· Drive Circuit: Drives transistors.
· Protection circuit: Protects transistors from over current.
Since the above components are all integrated in INTELLIGENT POWER MODULE, INTELLIGENT POWER MODULE has a 
merit to make the control circuit simplifi ed and miniaturized.
5. Elimination of electrical noise
NOISE FILTER CIRCUIT, which is formed by *CMC COILS, *NMC COILS and capacitors placed on the P.C. board, eliminates 
electrical noise of AC power that is supplied to main power supply circuit. This circuit also prevents the electrical noise gener-
ated in the inverter circuit from leaking out.
*CMC COILS: Common mode choke coils
*NMC COILS: Normal mode choke coils 
3-1-3. Sine wave control
In these air conditioners, compressor equips brushless DC motor which does not have Hall element.
In short, the motor is sensorless. However, it is necessary to locate the polar direction of rotor in order to drive brushless DC mo-
tor effi ciently. The general detection method of the polar direction for such a DC motor is to locate it from the voltage induced by 
unenergized stator.
Therefore, it is necessary to have a certain period of time in which the stator is being unenergized for the rotor position detection 
when the voltage of supplied power is impressed.
So the motor has been driven by square wave control (the conventional motor drive system) which energizes the motor only 
when the range of electrical angle is within 120° because it is forced to be unenergized within 30° at start and end of one heap 
in one waveform cycle (180°) when the voltage is impressed.
However, torque pulsation occurs at rotation in this method when the current-carrying phases are switched over to other phases 
in sequence. Therefore, sine wave control system is adopted for these air conditioners because it can make the phase-to-phase 
current waveform smoother (sine wave) in order to drive the motor more effi ciently and smoothly. 
3-1-4. Characteristics of sine wave control in case of brushless DC motor
 Although ordinary 3-phase induction motor requires energy to excite the magnetic fi eld of rotor, brushless DC motor does not 
need it. So, higher effi ciency and torque are provided.
 This control provides the most effi cient waveform corresponding to the rotational speed of compressor motor.
 The rotation can be set to higher compared to the conventional motor drive system. So, the time in which air conditioner can 
be operated with less energy is longer than conventional models. This can save annual electric consumption.
 Compared to square wave control, the torque pulsation is reduced at rotation so that the motor operates more quietly.
 Since the response and effi ciency of motor are enhanced in sine wave control, fi ner adjustment can be provided.
 
DC Motor
AC Motor
Rotor
Permanent magnet is embedded.
Excited by magnetic fi eld of stator
Rotor Position Signal
Necessary
Unnecessary
 In brushless DC motor, permanent magnet is embedded in the rotor. Therefore, it does not require energy to excite the rotor 
like AC motor does. However, it is necessary to control the frequency of 3-phase AC current supplied to the stator accord-
ing to the polar direction of magnet embedded in the rotor so as to drive the motor effi ciently. Controlling 3-phase AC current 
frequency also means controlling the timing to switch the polarity of stator. Therefore, the polar direction of rotor needs to be 
detected.
3-1-5. Control Method of Rotational speed
Sine wave control makes the current transformers conduct real time detection of the value of the current running into the mo-
tor, locates the rotor position from the detected value and decides if voltage should be impressed and if frequency should be 
changed.
Compared to the conventional control and rotor position detection method, sine wave control can provide fi ner adjustment of the 
voltage of supplied power. The value of the current running into the motor is determined by each motor characteristic.