 Warning: 
Never use needles, wires, or similar cylindrical objects to 
clean the pilot to avoid damaging the calibrated ruby that 
controls the gas flow.
Cleaning and Pilot Maintenance
Oxygen Depletion Sensor Pilot (Figure 17)
When the pilot has a large yellow tip flame, clean the Oxygen 
Depletion Sensor as follows:
1.  Clean the ODS pilot by loosening nut B from the pilot tubing. 
When this procedure is required, grasp nut A with an open end 
wrench.
2.  Blow air pressure through the holes indicated by the arrows. 
This will blow out foreign materials such as dust, lint and 
spider webs. Tighten nut B also by grasping nut A. 
Label all wires prior to disconnection when servicing controls. 
Wiring errors can cause improper and dangerous operation. Verify 
proper operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 
110 volts. Maximum length of 20 feet of 16 AWG to conductor 
wires is to be used with all optional switches.
Use  the  two  leads  (Red  and  Green)  to  attach  optional 
components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be checked 
with a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver adjacent to 
the gas valve.
Attention: The  remote  receiver  bracket  is  not  used  in  this 
installation.
1.  The remote receiver can not be placed behind the gas valve 
and burner assembly.
2.  When facing the appliance, the remote receiver must be placed 
to the right of the gas valve.
Install remote control receiver behind bottom louver.
Refer to remote control installation and operating instructions for 
more details on remote control.
Keep the control compartment, logs and burner area surrounding 
the logs clean by vacuuming or brushing area at least twice a 
year.
THE  LOGS  CAN  GET  VERY  HOT  –  HANDLE  ONLY 
WHEN COOL.
Always turn off gas to the pilot before cleaning. For relighting, 
refer to lighting instructions located on the rating plate of the 
log set.
Never obstruct the flow of the combustion and ventilation air. Keep 
the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.
Screens should be closed during operation.
Figure 18
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150
°
C DU L'EQUIVALENT.
THERMOPILE
GAS VALVE
THERMOCOUPLE
(NATURAL)
OFF
ON
REMOTE
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
WIRING DIAGRAM
GAS VALVE
VALVE DE GAZ
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
H
N
VEILLEUSE
PILOT
THERMOCOUPLE
(LPG)
WIRING
MAINTENANCE