Step 1
Open the door of your dryer
Step 2
Pull out the filter (using the 
two finger grips)
Step 3
Clean the fluff off the filter 
and replace it correctly. 
Ensure that the filter is 
pushed fully home.
Step 4
Make sure the filter is pushed fully home
NEVER 
run the dryer without the filter in  position
Failure to clean the filter after EVERY drying 
cycle will affect the drying performance of your 
machine. It will take longer to dry and as a result 
will use more electricity during drying.
At least every two or three months you MUST 
clean fluff build up around the filter housing and 
the vent tube. 
IDV 75 UK
IDV 75 S UK                  
                                         
IDV 75B K UK
WHERE TO INSTALL THE TUMBLE DRYER
10
 m
m
15 mm
15 mm
15 mm
15 mm
If you are going to install the 
appliance under a work 
counter be sure to leave a 
10 mm space between the 
top and any other objects on 
or above the machine and a 
15 mm space between the 
sides and any kitchen units 
or walls to ensure proper air circulation. The 
dryer must never be installed behind a lockable 
door, a sliding door or a door with a hinge on the 
opposite side to that of the dryer door.
The appliance must be installed with the rear 
surface placed against a wall
.
VENTILATION
When the dryer is in use there has to be adequate 
ventilation to avoid the back flow of gases into 
the room from appliances burning other fuels, 
including open fires. 
The vent tube should not exceed 2.4 
metres in length. The tube should be kept clear of the air intake 
vent and kinks or ‘U’ bends must be avoided as these will obstruct 
the tube and trap condensation. 
VENTING 
Wall mounting
Keep the tube as short and as straight 
as possible to prevent condensation 
forming in the vent pipe.
The duct in the wall should slope 
slightly downwards.
Window mounting
The hole in the window should be as 
low down as possible and the tube should be kept as short as 
possible.Depending on how often you use your tumble dryer, it is 
essential that areas 
A
 and 
B
 are checked periodically to remove 
lint or debris. 
 This symbol reminds you to read this booklet.
B
A
Open window venting
The end of the tube should be 
directed downwards, to prevent 
warm moist air from condensing in 
the room or dryer.
Do not discharge exhaust 
air into a flue which is used 
for exhaust fumes from 
other appliances that burn gas or other fuels. 
Do not discharge exhaust air into an extraction system or any duct 
with an extractor fan. This will affect the way the thermal controls 
operate and can result in a fire hazard.
ELECTRICAL CONNECTIONS
The socket must be grounded. The power supply 
cord should be checked periodically. If the 
supply cord is damaged, it must be replaced by 
the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazar
LEVELLING YOUR DRYER
The dryer must be installed level for 
correct operation. When you have 
installed your dryer in its final location 
check that it is first level side to side and 
then back to front.
If the dryer is not level use a wooden 
block to support it while adjusting the 
two front legs up or down until your dryer is level.
BEFORE YOU START USING YOUR DRYER
Once you have installed your dryer and before you 
use it clean the inside of the drum to remove any 
dust that could have accumulated during transport
.
Air intake vent 
Do not block or obstruct
Caution: Hot!
Vent Tube fitted here