Fujitsu TX200 S3 User Manual

Page of 10
*1. By applying Internal HDD Unit Bay Conversion kit (PG-BC103), 5 inch bay x 2 can be converted
     to 3.5 inch bay x 2.
     When Internal HDD Unit Bay Conversion kit (PG-BC103) is applied, Internal Backup Device
     cannot be mounted on 5inch Bay.
*2. By applying Power Supply Conversion kit (PGBRSU104), non-redundant structure (Power Supply x1,
     FAN x2) can be converted to redundant structure (Power Supply x2, FAN x6).
*3. Frequency will be changed by the spec of PCI card and number of cards mounted.
*Components installed as standard configuration marked in grey.
PCI Slot
* No AFT/ALB Support
* [n] : Installation Priority
* #   : standard
* -    : cannot be installed
*1.Frequency will be changed by the spec of PCI card and number of cards mounted.
-
Eth. Ctrl 1x1Gbit PCI-E
1000BASE-SX
PG-288
PCI Express
(x4)
-
-
[1]
[2]
-
[2]
[2]
2
2
PCI Express Card
-
PCI Express Card
PCI Express Card
-
PCI Express Card
-
2
2
[3]
Internal/External SCSI
Controller
Fibre Channel Controller
PG-FC202 /
PGBFC202
PCI Express
(x4)
-
-
-
[1]
[2]
[2]
[1]
-
-
SCSI Ctrl U160
PG-1281 /
PGB1281
PCI/64bit
-
[2]
[1]
-
-
-
RAID Ctrl 2-Channel 128MB
w/ BBU
PG-142E3 /
PGB142E3
PCI/64bit
-
Eth. Ctrl 2x1Gbit PCI-X
1000-BASE-T
PG-1863
PCI-X/64bit
-
[1]
[2]
-
-
-
[3]
[1]
[2]
-
-
[3]
-
-
Eth. Ctrl 1000-BASE-T Cu
PG-1892 /
PGB1892
PCI-X/64bit
-
-
[3]
Internal array
External array
2
[3]
2
[3]
2
Standard, Internal array
1
PG-140G /
PGB140G
PCI-X/64bit
-
[1]
-
-
-
Internal array
SAS RAID Ctrl
PG-140F /
PGB140F
PCI-X/64bit
-
SAS Controller
(8ports)
-
PCI-X/64bit
#
-
Remarks
10
1
2
3
4
5
PCI-X
PCI Express
PCI
x8
lane
x4
lane
32bit/
33MHz
Full Height
Mountable Cards
Bus
64bit/
100MHz
64bit/
100MHz *1
3.3V
Mount
Priority
Eth. Ctrl 2x1Gbit PCI-E
1000-BASE-T
PG-2861 /
PGB2861
PCI Express
(x4)
-
-
-
[1]
[1]
-
[1]
[2]
-
[1]
[2]
 Max No.
of Mount
3
2
2
1
1
1
2
2
-
x8 socket
5.0V
-
-
-
-
-
-
-
SAS RAID Ctrl
Eth. Ctrl 1x1Gbit PCI-E
1000-BASE-T
PG-289 /
PGB289
PCI Express
(x1)
Eth. Ctrl 1x1Gbit PCI
1000-BASE-T
PG-1853 /
PGB1853
PCI/32bit
Eth. Ctrl 1000-BASE-SX
Fibre LC
PG-1882
PCI-X/64bit
-
-
-
[1]
Configuration Diagram
Power Supply Unit
PCI Slots
  5 inch Bay 3
  5 inch Bay 2
  5 inch Bay 1
 CD-ROM Drive / FDD
Mountable I/O Options
PRIMERGY  TX200 S3
Memory
  DIMM Slot 3B
  DIMM Slot 2B
  DIMM Slot 1B
  DIMM Slot 3A
  DIMM Slot 2A
Power Supply Unit
  DIMM Slot 1A
CPU
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
 3.5 inch HDD Bay 6
          (hot plug)
 3.5 inch HDD Bay 5
          (hot plug)
 3.5 inch HDD Bay 4
          (hot plug)
 3.5 inch HDD Bay 3
          (hot plug)
 3.5 inch HDD Bay 2
          (hot plug)
 3.5 inch HDD Bay 1
          (hot plug)
*2
*1
Bay 6
SAS
Bay 5
SAS
Bay 4
SAS
Bay 3
SAS
Bay 2
SAS
Bay 1
SAS
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage ( HDD x 6ports )
Bay 7
SAS
Bay 8
SAS
When Internal HDD Unit Bay Conversion kit (PG-
BC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
  PCI5 PCI 32bit/33MHz
  PCI4 PCI Express (x4)
  PCI2 PCI-X 64bit/100MHz *3
  PCI3 PCI Express (x8)
  PCI1 PCI-X 64bit/100MHz *3
  PCI10 PCI-X 64bit/100MHz
High
Low
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
High
Low