SERVICE (cont.)
TANK HEATER SWITCH (cont.)
15. Set tank assembly inside the hood on  mounting
brackets and secure with two #8-32 screws.
16. Reconnect the wires to the limit thermostat, tank
heater and the control thermostat. Refer to limit
thermostat, tank heater and control thermostat
sections in this manual when reconnecting wires.
17. Brewers with faucet reinstall the faucet tube and
reconnect the water supply tube to the coil as-
sembly.
18. Secure the sprayhead tube to the hood using  hex
nut.
19. Install sprayhead.
20. Install fill basin, inlet gasket and secure to tank lid
with tank inlet fitting.
21. Carefully install  water  fill  tube into the back of the
fill basin.
22. Reconnect and turn on the incoming water sup-
ply.
23. Refer to the illustration below when reconnecting
the wires.
BLK to Terminal Block
(Black Insert)
BLK to Limit Thermostat
P1135
TIMER