Monessen Hearth CDVR33N/PV7 User Manual

Page of 68
CDVSC7 & CDV7 Series Gas Fireplace
40
69D3011
opTIonal Fan BloweR SySTeMS
BloT auToMaTIC TheRMoSTaT BloweR
Figure 58 - 
BLOT Blower Wiring Diagram
BLACK
BLACK
WHITE
GREEN
BLACK
BLACK
WHITE
Receptacle 
Junction 
Box
120VAC
Speed Control 
FP2675
BLOT blower wiring
FP675
Before  installing  the  blower,  wire  the  receptacle  into  an 
electrical circuit. This should be done before framing the 
fireplace.  Wire  with  minimum  60°  C  wire  in  accordance 
with prevailing codes.
FK-12 Manual BloweR
1.   This must be done before framing the fireplace. When 
installing the FK-1 blower, a wall switch control must 
be installed to control the blower. 
.  The fireplace power supply is wired through the blower 
wall switch and then brought to the fireplace junction 
box.
3.  The  jumper  clip  on  the  plug  receptacle  must  be  re-
moved. Figure 59. Use needlenose pliers to break off 
the jumper clip.
Junction Box
Blower
Wall Switch
Black (live)
Green (ground)
White (neutral)
Red
Black
FK-12 Blower
Plug into switch outlet
FP2676
FK12 wiring
Jumper clip on plug 
receptacle must be 
removed on power side to 
make outlet switchable
Figure 59 - 
FK-12 Blower wiring Diagram
FP676