noTe ReGaRDInG VenTeD pRoDuCTS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
Any  residence  with  a  direct  vent  product  must  have  a  CO 
detector installed in the residence.
Installation  of  the  fireplace  or  vented  gas  log  in  the  State 
of  Massachusetts  requires  the  damper  to  be  permanently 
removed or welded in the fully open position.
In addition, a naturally vented gas log may not be installed in a 
bedroom or bathroom in the State of Massachusetts.
Flex  line  installation  must  not  exceed  36  inches  and  must 
have a T shutoff valve. 
noTe ReGaRDInG VenT FRee pRoDuCTS
This product must be installed by a licensed plumber or gas fitter 
when installed within the Commonwealth of Massachusetts.
In  addition,  vent  free  products  may  not  be  installed  in  a 
bedroom or bathroom regardless of size or type in the State 
of Massachusetts.
Flex  line  installation  must  not  exceed  36  inches  and  must 
have a T shutoff valve.
CaRBon MonoxIDe DeTeCToR RequIReMenTS
() Revise  10.8.3  by  adding  the  following  additional 
requirements:
(a)  
For  all  side  wall  horizontally  vented  gas  fueled 
equipment  installed  in  every  dwelling,  building  or  structure 
used  in  whole  or  in  part  for  residential  purposes,  including 
those owned or operated by the Commonwealth and where the 
side wall exhaust vent termination is less than seven (7) feet 
above finished grade in the area of the venting, including but 
not limited to decks and porches, the following requirements 
shall be satisfied:
1. Installation of carbon monoxide detectors. At the time 
of  installation  of  the  side  wall  horizontal  vented  gas  fueled 
equipment,  the  installing  plumber  or  gas  fitter  shall  observe 
that a hard wired carbon monoxide detector with an alarm and 
battery back-up is installed on the floor level where the gas 
equipment is to be installed. In addition, the installing plumber 
or gas fitter shall observe that a battery operated or hard wired 
carbon monoxide detector with an alarm is installed on each 
additional  level  of  the  dwelling,  building  or  structure  served 
by  the  side  wall  horizontal  vented  gas  fueled  equipment.  It 
shall be the responsibility of the property owner to secure the 
services of qualified licensed professionals for the installation 
of hard wired carbon monoxide detectors
 
a.  In the event that the side wall horizontally vented gas 
fueled equipment is installed in a crawl space or an attic, the 
hard wired carbon monoxide detector with alarm and battery 
back-up may be installed on the next adjacent floor level.
 
b.  In the event that the requirements of this subdivision 
can  not  be  met  at  the  time  of  completion  of  installation,  the 
owner shall have a period of thirty (30) days to comply with the 
above requirements; provided, however, that during said thirty 
(30) day period, a battery operated carbon monoxide detector 
with an alarm shall be installed.
Massachusetts Residents only — please read and follow these special requirements
.  approved  Carbon  Monoxide  Detectors.  Each  carbon 
monoxide detector as required in accordance with the above 
provisions shall comply with NFPA 70 and be ANSI/UL 034 
listed and IAS certified.
3.  Signage.  A  metal  or  plastic  identification  plate  shall  be 
permanently  mounted  to  the  exterior  of  the  building  at  a 
minimum height of eight (8) feet above grade directly in line 
with  the  exhaust  vent  terminal  for  the  horizontally  vented 
gas  fueled  heating  appliance  or  equipment.  The  sign  shall 
read,  in  print  size  no  less  than  one-half  (1/)  inch  in  size, 
“GAS  VENT  DIRECTLY  BELOW.  KEEP  CLEAR  OF  ALL 
OBSTRUCTIONS.”
4.  Inspection.  The  state  or  local  gas  inspector  of  the  side 
wall  horizontally  vented  gas  fueled  equipment  shall  not 
approve the installation unless, upon inspection, the inspector 
observes  carbon  monoxide  detectors  and  signage  installed 
in  accordance  with  the  provisions  of  48  CMR  5.08()(a)1 
through 4.
(b) exemptions: The following equipment is exempt from 48 
CMR 5.08()(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not 
Required To Be Vented" in the most current edition of NFPA 54 
as adopted by the Board; and
. Product Approved side wall horizontally vented gas fueled 
equipment installed in a room or structure separate from the 
dwelling,  building  or  structure  used  in  whole  or  in  part  for 
residential purposes.
(c)  Manufacturer requirements — Gas equipment Venting 
System  provided.
  When  the  manufacturer  of  Product 
Approved side wall horizontally vented gas equipment provides 
a venting system design or venting system components with 
the equipment, the instructions provided by the manufacturer 
for installation of the equipment and the venting system shall 
include:
1. Detailed instructions for the installation of the venting system 
design or the venting system components; and
. A complete parts list for the venting system design or venting 
system.
(d) Manufacturer requirements — Gas equipment Venting 
System not provided. 
When the manufacturer of a Product 
Approved side wall horizontally vented gas fueled equipment 
does  not  provide  the  parts  for  venting  the  flue  gases,  but 
identifies “special venting systems,” the following requirements 
shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall 
be  included  with  the  appliance  or  equipment  installation 
instructions; and
. The “special venting systems” shall be Product Approved 
by the Board, and the instructions for that system shall include 
a parts list and detailed installation instructions.
(e)  
A  copy  of  all  installation  instructions  for  all  Product 
Approved side wall horizontally vented gas fueled equipment, 
all venting instructions, all parts lists for venting instructions, 
and/or all venting design