BLDV7 Series Gas Fireplace
InStaLLatIon preCautIonS
Consult  local  building  codes  before  beginning  the 
installation.  The  installer  must  make  sure  to  select  the 
proper vent system for installation. Before installing vent 
kit, the installer must read this fireplace manual and vent 
kit instructions. 
Only a qualified installer/service person should install vent-
ing system. The installer must follow these safety rules:
  Wear gloves and safety glasses for protection.
  Use extreme caution when using ladders or when 
on rooftops.
•  
Be aware of electrical wiring locations in walls and 
ceilings.
The following actions will void the warranty on your vent-
ing system:
  Installation of any damaged venting component.
•  
Unauthorized modification of the venting system.
•  
Installation of any component part not manufactured 
or approved by MHSC.
•  
Installation  other  than  permitted  by  these  instruc-
tions. 
VentInG InStaLLatIon InForMatIon
w
arn
In
G
read all instructions completely and thoroughly before attempting installation. Failure 
to do so could result in serious injury, property damage or loss of life. operation of 
improperly installed and maintained venting system could result in serious injury, 
property damage or loss of life.
not
IC
e
Failure to follow these instructions will 
void the warranty.
this  fireplace  must  be  vented  to  the 
outside. the venting system must neVer 
be  attached  to  a  chimney  serving  a 
separate  solid  fuel  burning  appliance. 
each gas appliance must use a separate 
vent  system.  Do  not  use  common  vent 
systems.
w
arn
In
G
GeneraL VentInG
Your fireplace is approved to be vented either through the 
side wall, or vertical through the roof.
  only  MhSC  venting  components  specifically  ap-
proved  and  labelled  for  this  fireplace  may  be 
used.
•  
Flexible  UL1777  listed  venting  may  be  used  in  any 
venting application where rigid direct vent components 
can be used. All restrictions, clearances and allowanc-
es that pertain to the rigid piping apply to the flexible 
venting.
  Flex kits may not be modified. Flex kits may be added 
to  the  end  of  a  vent  run  made  of  rigid  vent  sections 
using pipe manufacturer's approved flex to pipe adapt-
ers. This may occur only if doing so does not violate 
any of the venting length, height, routing, horizontal to 
vertical raito requirements or clearance considerations 
detailed in this manual. 
  Venting terminals shall not be recessed into a wall or 
siding.
  Horizontal  venting  which  incorporates  the  twist  lock 
pipe must be installed on a level plane without an in-
clining or declining slope.
  Horizontal venting which incorporates the use of flex 
venting shall have an inclining slope from the unit of 1” 
(5 mm) per 4” (610 mm).
There must not be any obstruction such as bushes, gar-
den  sheds,  fences,  decks  or  utility  buildings  within  4” 
(610 mm) from the front of the termination hood.
Do not locate termination hood where excessive snow or 
ice  build  up  may  occur.  Be  sure  to  check  vent  termina-
tion area after snow falls, and clear to prevent accidental 
blockage of venting system. When using snow blowers, 
make sure snow is not directed towards vent termination 
area.
Location of Vent termination 
It is imperative the vent termination be located observing 
the minimum clearances as shown on following page.
always  maintain  minimum  clearances  around  vent  systems.  the  minimum  clearances  to 
combustibles for horizontal vent pipe are 3" at the top* and 1" at the sides and bottom of the 
vent system until the pipe penetrates the nearest vertical wall (1" required). a 1" minimum 
clearance all around the pipe must be maintained at outside wall and on vertical runs. Do not 
pack the open air spaces with insulation or other materials. this could cause high temperatures 
and may present a fire hazard.
*  unless  the  vertical  run  is  7Z\x  feet  or  higher  (top  vent  units  only),  the  clearances  for  the 
horizontal run is 1" at the top.
w
arn
In