BLDV7 Series Gas Fireplace
SIGnature CoMManD - eLeCtrICaL InStaLLatIon 
junCtIon Box wIrInG
1.  This  should  be  done  before  framing  the fireplace.  Wire the  receptacle  into  an  electrical  circuit. 
Wire with minimum 60° C wire in accordance with prevailing 
codes.
.  Remove  the  external  junction  box  cover  by  removing  the 
screw from the side of the outside firebox wall. Junction box 
was installed at the factory.
3.  The junction box cover has a factory installed “romex” style 
strain relief connector. After connecting the wires, route the 
wire leads through this connector. Refer to the wiring dia-
gram in Figure 48.
Figure 48 - 
Junction Box Wiring Diagram
FP1912
Junction box wiring
8/08
Junction Box
Factory Supplied
Not Supplied
10V AC
60Hz
CoMManD Center waLL InStaLLatIon
The command center may be mounted on the wall with 
the use of the SCSWEK Kit (15ft. cable, junction box, wall 
cover).
Mount  the  junction  box  provided  at  the  desired  location 
on the wall. Do not extend beyond the 15 ft. wire cable 
provided. If a longer distance is required, the 15 ft. may be 
extended up to 30 ft. maximum by using two () SCSWEK 
cables plugged together.
Route the wire from junction box to lower control area at 
bottom of fireplace. Unplug the 1" cable from the com-
mand center. Attach the connector to the pins from wire 
by pushing in to connector making sure to follow the color 
code on connector. Plug the 15 ft. extension cable into the 
 ft. cable. Remove command center from the fireplace 
and  plug  the  other  end  of  the  extension  cable  into  the 
command center. Snap on wall cover provided and screw 
to junction box.
waLL SwItCh InStaLLatIon
The wall switch wire connection is located off the  ft. wire 
harness from the control box to the command center. Fig-
ure 49.
 The connection is labeled “Wall Switch”. Unplug 
the male and female connectors and connect the two () 
low voltage wires provided. Run wire to desired location 
on wall. Up to 50 ft. of 18 ga. wire may be used if neces-
sary. Attach wires to wall switch. Mount the wall switch in 
to junction box and screw on cover.
w
arn
In
G
Do  not  connect  wall  switch  to  110  V 
circuit.