Monessen Hearth CDVR33N/PV7 User Manual

Page of 60
74D3000
5
BLDV7 Series Gas Fireplace
proDuCt FeatureS
  This  appliance  has  been  certified  for  use  with  either 
natural or propane gas. See appropriate data plates.
  This appliance is not for use with solid fuels.
  The  appliance  is  approved  for  bedroom  or  bedsitting 
room installations.
  The appliance must be installed in accordance with local 
codes if any. If none exist use the current installation 
code. ANSI Z3.1/NFPA 54 in the USA, CSA B149 in 
Canada.
  This appliance is mobile home appr-oved.
  The appliance must be properly connected to a venting 
system.
  The  appliance  is  not  approved  for  closet  or  recessed 
installations.
proDuCt SpeCIFICatIonS
FP2073
BLDV controls
Off/Pilot/On Knob 
Figure 1 - 
BLDV7 Series Fireplace 
(Millivolt Control shown)
Hi/Lo Knob 
On/Off/RS 
Switch 
Ignitor
FP073
hIGh eLeVatIonS
Input ratings are shown in BTU per hour and are certified 
without deration for elevations up to 4,500 feet (1,370 
m) above sea level.
For  elevations  above  4,500  feet  (1,370  m)  in  USA, 
installations  must  be  in  accordance  with  the  current 
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties  having  jurisdiction  for  installations  at  elevations 
above 4,500 feet (1,370 m).
GaS preSSureS
   
Natural 
Propane (LP)
  Inlet Minimum 
4.5” w.c. 
11.0” w.c.
  Inlet Maximum 
10.5” w.c. 
13.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
GaS SpeCIFICatIonS & orIFICe SIZe
 
  
 
Max.Input  Min. Input 
Orifice 
  Model 
Fuel 
BTU/h 
BTU/h 
Size
  BLDV400NV7 
Nat. 
6,000 
1,000 
.5 mm
  BLDV400PV7 
LP 
6,000 
1,000 
1/16 in.
  BLDV400NSC7  Nat. 
6,000 
19,000 
.5 mm
  BLDV400PSC7 
LP 
6,000 
1,000 
1/16 in.
  BLDV500NV7 
Nat. 
8,000 
0,000 
#38
  BLDV500PV7 
LP 
7,000 
,000 
1.55 mm
  BLDV500NSC7  Nat. 
8,000 
0,000 
#38
  BLDV500PSC7 
LP 
7,000 
,000 
1.55 mm