Jacuzzi J-345 User Manual
14
J-300
Export J-335, J-345, J-355, J-365, J-375 and J-385 Models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
RCD Breaker:
20A
30A
40A
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
Wattage:
3.5 kW
5.3 kW
6.7 kW
* In 20A configuration, the heater will not operate while either jets
pump is running.
This is the factory setting.
** In 30A configuration, the heater will operate while one jets pump
is running.
*** In 40A configuration the heater will operate while both jets pumps
are running.
Export J-315 and J-325 Models (50 Hz)
230V/20A*
230V/30A**
RCD Breaker:
20A
30A
Number of Wires:
3
3
Frequency:
50 Hz
50 Hz
Current Draw:
15A
21A
Wattage:
3.5 kW
4.8 kW
* In 20A configuration, the heater will not operate while the jets
pump is running.
This is the factory setting.
** In 30A configuration, the heater will operate while the jets pump is
running.