Jacuzzi J-345 User Manual

Page of 72
48
J-300 
14. 
System Test 1: Assure there is no water dripping from the seal 
compression nut (7). If water is visible, STOP and tighten the 
compression nut (7) using a pair of channel lock pliers to a maximum 
of 1/4 turn. If that does not fix the leak, then repeat quartz tube 
maintenance process from step 1 through step 13. Make sure there 
is no water leaking before proceeding to step 15.
15. 
System Test 2: Reconnect the CLEARRAY System to the controller. 
Turn breaker back ON. Turn on the pump to circulate the water 
through the CLEAR
RAY System. Wait for 5 minutes and assure no 
water is dripping. If water is visible, STOP, fix the leak by repeating 
quartz tube maintenance process from step 1 through step 14. 
Make sure there is no water visible. Turn the pump and breaker 
OFF and disconnect the CLEARRAY System from the controller 
BEFORE proceeding to step 16.
16. Reconnect the bulb socket (5) to the new UV bulb (4) make sure you 
use the latex glove provided when handling the UV bulb.
Note:
 Align pins on UV bulb (4) to the receptacle holes on the bulb socket 
(5) before inserting the pins completely into socket holes. Failure to do so 
will damage the UV bulb.
17. Slide the new UV bulb (4) back inside the quartz tube, Figure 3.
18. Reinstall the black bulb boot (8) back over the quartz seal 
compression nut (7).
19. Reinstall the enclosure cover (10) with gasket (9) and secure with 
the screws.
20. Reconnect the CLEAR
RAY System to the controller and turn on the 
power to the spa.
21. Properly dispose of the old UV bulb.
22. Once power is activated you can check the 
ballast (12), Figure 7, to see if the CLEAR
RAY 
System is functioning. A solid green light indicates 
that the CLEAR
RAY System is being provided 
power and should always be on. A solid red light 
indicates that UV bulb is activated.
WARNING:
 DO NOT TOUCH THE NEW UV BULB WITH 
YOUR BARE HAND. Oil on your skin will cause hot spot on  
the UV bulb and shorten the life of your UV bulb. Use the pro-
vided latex glove to handle the UV bulb.
!
120 - 230V
Indicator
Lights
Figure 7
WARNING:
 This CLEAR
RAY System includes a UV bulb, 
which contains mercury. Dispose of the bulb in accordance  
!