Jacuzzi J-345 User Manual

Page of 72
54
J-300 
16.2  North American J-315 and J-325 Convertible Power Models  
(60 Hz)
This wiring diagram is used for all North American 120/240V 60 Hz 
convertible power models.
Note: Optional 120/240 VAC 4-wire connection enhances heater output 
from 1kW to 4kW.
DANGER
Turn power off 
before servicing. This 
task should only be 
performed by a quali-
fied technician.
!
RISK OF SHOCK OR 
ELECTROCUTION!
Ports 1-10 
power spa 
lights, waterfall 
lights and step 
lights on 
applicable 
models
Light DCU
1
2
3
4
5
6
7
8
9
10
POWER
EXP BAR
EXP BAR
CLEAR
RAY
Standard 120 VAC 3-Wire Connection (60 Hz, 1 Phase, 15A Service), 
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST MEET NEC RECOMMENDATIONS 
AND/OR LOCAL CODES AND IS DETERMINED BY MAXIMUM CURRENT DRAW AND 
LENGTH OF RUN. 
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
RED
RED
*
RED
*
RED
*
RED
Heater
1.0 kW @ 120 VAC (3-wire connection)
4.0 kW @ 240 VAC (4-wire connection)
Pressure Switch
Hi-limit/Freeze Sensor
Temperature Sensor
J2
J3
F1
20A
250V
SC-20
Main Pump
Transformer
120 VAC
Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.
Optional 4-Wire 240/120 VAC Convertible Heater Connection
1.  Remove and discard the factory installed GFCI Cord.
2. Move 
RED
wire from TB1 position #1 to TB1 position #3 as shown.
3.  Permanently connect to the power supply.  
4.  If hot tub is to be operated on 30A service, make sure the jumper provided at location JP1 #1 & 2 on the circuit board is installed. 
     If  hot tub is to be operated on 40A service, remove the jumper  JP1 #1 & 2 on the circuit  board.
HI
J1 Logic Jumper Settings
JP1 1-2 ON    =  30A Logic (4-wire 120/240 VAC operation only)
JP1 1-2 OFF  =  40A Logic (4-wire 120/240 VAC operation only)
JP1 7-8 ON    = °C Temperature Display
JP1 7-8 OFF  = °F Temperature Display
This device complies with Part 15 of the
FCC rules.  Operation is subject to the 
following two conditions:
1.  This device may not cause harmful 
  interference.
2.  This device must accept any inteference 
  received including interference that may 
  cause undesired operation.
J20
J21
J12
J14
J16
J11
J15
J13
J17
J7
J8
J9
J10
J5
J6
Heater IN
Heater OUT
F1
K5
K7
K8
J1
Control 
Panel
7
5
3
1
8
6
4
2
To circuit board
GRN
TB1
WHT
BLK
3
2
1
3
2
1
GROUND
GRN
TB1
WHT
BLK
RED
GROUND
WARNING, ELECTRICAL SHOCK HAZARD EXISTS!  
Hard
Wire 
Only
Plug-in 
GFCI 
Cord (US 
Models 
Only) OR
Hard 
Wire
EXTERNAL SERVICE PANEL 
BOX DISCONNECT MEANS 
MUST BE LOCATED NO CLOSER 
THAN 5 FT. (1.52m) FROM THE 
INSIDE WALLS OF THE SPA AND 
WITHIN SIGHT OF SPA 
MAIN POWER
ON//OFF SHUTOFF
SWITCH 
C
Circ.
Pump
(Not offered 
on all models)
THERM 
SWITCH
(Located inside the heater for certain models)
Control 
Panel
Always remove power to spa before wiring and/or configuring the circuit board. 
Mini-Din Cable provides 
constant 12VAC from 
yellow transformer wires
Mini-Din Control 
Panel Cable
(Not offered on all models) 
BLK
WHT
OZONE
STEREO POWER SUPPLY
(Not offered on all models)
(Not offered on all models)
SPA LIGHT